Table 14. Drop-Down List Selections Output Devices

Designation Function

No Function

The output is always inactive.

Call Received

Becomes active when a confirmed call connection occurs.

Call Placed

Becomes active at the start of a voice call and will become inactive when a
confirmed call connection occurs.

Answer Voice Call Becomes active at the start of a voice call that is being received by the telephone.

Track Ringing

Is only active while the telephone is generating a simulated ring-back tone after an
incoming call is received.

Non-Keypad Voice
Call

Becomes active at the start of a voice call that is not dialed using the keypad.

Keypad Voice Call Becomes active at the start of a voice call that is dialed using the keypad.

Any Call

Becomes active at the start of any call, whether inbound or outbound.

Alerter 20 Hz
Warble

Provides a pulsed dc signal for the piezo ringer to produce a simulated ringing tone
on an incoming call if the Ringing (Manual Answer) feature is enabled in the
“Behavior” properties.

Emergency Strobe Becomes active at the start of an Emergency call and is intended to control an

external strobe.

LED Flash/Solid
@ Connect

The output pulses at the start of a voice call and then becomes active in a steady
state when a confirmed call connection occurs.

Open Gate
Contact

The output pulses when the phone receives the proper “Open Gate Command” set
in the “Behavior” properties.

Mirror Handset
Hookswitch

The output follows the state of the handset cradle hookswitch.