GAI-Tronics TMA Version 7.5.0 Telephone Management Application (TMA) User Guide (Ver. 7.5.0 and newer) User Manual
Page 45
Pub. 42004-479B
Telephone Management Application (TMA) User Guide
Page 42 of 128
e:\standard ioms - current release\42004 instr. manuals\42004-479b.doc
03/14
Table 14. Drop-Down List Selections Output Devices
Designation Function
No Function
The output is always inactive.
Call Received
Becomes active when a confirmed call connection occurs.
Call Placed
Becomes active at the start of a voice call and will become inactive when a
confirmed call connection occurs.
Answer Voice Call Becomes active at the start of a voice call that is being received by the telephone.
Track Ringing
Is only active while the telephone is generating a simulated ring-back tone after an
incoming call is received.
Non-Keypad Voice
Call
Becomes active at the start of a voice call that is not dialed using the keypad.
Keypad Voice Call Becomes active at the start of a voice call that is dialed using the keypad.
Any Call
Becomes active at the start of any call, whether inbound or outbound.
Alerter 20 Hz
Warble
Provides a pulsed dc signal for the piezo ringer to produce a simulated ringing tone
on an incoming call if the Ringing (Manual Answer) feature is enabled in the
“Behavior” properties.
Emergency Strobe Becomes active at the start of an Emergency call and is intended to control an
external strobe.
LED Flash/Solid
@ Connect
The output pulses at the start of a voice call and then becomes active in a steady
state when a confirmed call connection occurs.
Open Gate
Contact
The output pulses when the phone receives the proper “Open Gate Command” set
in the “Behavior” properties.
Mirror Handset
Hookswitch
The output follows the state of the handset cradle hookswitch.