Pub. 42004-479B

Telephone Management Application (TMA) User Guide

Page 32 of 128

e:\standard ioms - current release\42004 instr. manuals\42004-479b.doc
03/14

Call-In Configuration

The Call-In Properties Form for a Type A Hands-free phone record is shown below followed by an
explanation of each parameter.

Table 7. Call-In Properties Parameters and Their Functions

Parameter Function

Call-In Schedule The Call-In Schedule determines the frequency at which the telephone is to call

TMA to provide an update. This field has four entries, which are:

Disable – disables the call-in feature.

Daily – directs the telephone to call in on a daily basis at the time set in the “Call-In
Time” field.

Every n hours – directs the telephone to call-in every “n” hours based on the
number selected in the “Call-In Interval” field.

Out of Service – sets a flag for TMA that the telephone is currently “out of service.”
This setting prevents TMA from polling the telephone.

Call-In Interval

The Call-In Interval sets the number of times the call-in process will occur with “n”
representing the number of hours between call-ins.
Example: If the telephone is configured for Every n hours in the Call-In Schedule
and this field is set to “2,” the telephone will call in every 2-hours.
N

OTE

: Telephones configured to call in Daily in the Call-In Schedule will ignore

this interval and will call in only at the time specified in the Call-In Time field.