Behavior – GAI-Tronics TMA Version 7.5.0 Telephone Management Application (TMA) User Guide (Ver. 7.5.0 and newer) User Manual

Page 49

Advertising
background image

Pub. 42004-479B

Telephone Management Application (TMA) User Guide

Page 46 of 128

e:\standard ioms - current release\42004 instr. manuals\42004-479b.doc
03/14

Behavior

The Behavior tab on the Phone Properties sheet is shown below.

Behavior Properties

Speech Send Level The volume level of the speech being sent from the phone can be adjusted by setting
this parameter. The range in settings is from 0 to 50 dB. This is a phone’s internal gain setting; it is not
measured in dBm as the phone’s line level would be.

Speech Receive Level The volume level of the speech being received by the phone can be adjusted by
setting this parameter. The range in settings is from 0 to 50 dB. This is a phone’s internal gain setting; it
is not measured in dBm as the phone’s line level would be.

Rings Before Auto Answer S.M.A.R.T. phones can be programmed to ring a set number of times prior
to auto answering. The range is 0 to 15 rings. [In this version of TMA, auto answer of single line phones
cannot be disabled.]

After Auto Answer S.M.A.R.T. phones can be programmed to ring a set number of times after auto
answering. The range is 0 to 15 rings.

Timeout Period This parameter sets the maximum permissible duration of a speech call. After the
timeout period has elapsed, the phone will automatically terminate the speech call. This number
represents the number of tens of seconds, e.g. 9 = 90 seconds. The valid range is 6 (60 seconds) to 998
(2:46:20)
and 999 (timeout disabled).

Advertising