Appendix a: data file formats, A.1. sample syslog file, A.1.1. format – MultiDyne ACI-2058 User Manual

Page 183: Sample syslog file, Format, Data file formats, Appendix a

Advertising
background image

A54-3000-100 A

144

A

PCON

, Inc.

Data File Formats

A.1.

Sample SysLog File

For information about setting up your switch to write events to a SysLog, see the Enable
Remote Syslog option in

Service Properties

on page 117.

Events written to a logfile include:

Powering on or off a blade.

Patching or unpatching a port.

Naming a port.

Storing, recalling, naming, or getting the name of a preset configuration.

Setting the data rate, duplex setting, or MDI/MDIX status of a port.

Setting the TCP/IP parameters of the I

NTELLA

P

ATCH

switch.

Setting the device number of the I

NTELLA

P

ATCH

switch.

Enabling or disabling the Telnet interface, or its secure (SSH) variant.

Enabling a remote SysLog file, or getting or setting the IP address of the computer to
which to write it.

Requiring secure logins.

Resetting the I

NTELLA

P

ATCH

switch to its factory defaults.

Specifying an event type(Facility) and importance (Severity). For details about available
choices, see the Facility/Severity option on the Event Log screen. For details about this
screen, see page 82.

A.1.1.

Format

The messages consist of:

[date] [serverIP] [switchname] apcond/[service]: [action]|b:[blade]
p:[port] u:[user]@[IP] [string]

— OR —

[date] [serverIP] [switchname] apcond/[service]: [action]|b:[blade]
p:[port] u:[user]/[remoteIP]@[IP] [string]

Appendix A

Data File Formats

Appendix A

For information about...Go to this page...

Sample SysLog File

................................................................................................... 144

Import/Export File Formats

......................................................................................... 147

Export Users File Format

............................................................................................ 148

Advertising