Chapter 3 Installing the Level 2R Storage System

iSCSI Bridge Server
Configuration

This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
Fibre Channel connection to
the RAID storage. You
configure network settings
on the iSCSI adapters and
the page validates that the
Fibre Channel adapter is in
place and that the media
LUNs are visible as iSCSI
targets.

For Level 2 redundant, select

Primary

.

Select an iSCSI adapter and click

Modify

. A network configuration

dialog box opens. Enter the media network IP address and the subnet
mask and click

Apply

. Do the same for the other iSCSI adapter.

Click

Check

. The Validation Report opens.

Confirm that the iSCSI configuration is successful. Close the Validation
Report and then click

Next

.

Database Server
Configuration

Enter the name or IP address of K2 Media server B. This is the redundant
partner of the server you are now configuring.
Click

Next

.

On this page…

Do this…