Recovering from a failed K2 Media Server system battery

When the system battery in a K2 Media Server fails (non rechargeable) the system
configuration is lost, and the system will not complete startup processes when the
battery is replaced.

To recover from a failed battery, do the following:

1. Restart the K2 Media Server.

A startup screen displays the message “Invalid configuration information - Please
run setup program. Time of day not set - Please run setup program.”

2. Press

F2

to enter setup.

3. Set the system date and time

4. Select

System Setup | Integrated Devices

5. Select

RAID

. This also sets ChA and ChB to RAID

6. Restart the K2 Media Server.

A startup screen displays the message “Warning: Detected mode change from
SCSI to RAID on ChA of the embedded RAID system.”

7. Select

Yes

.

A startup screen displays the message “Warning: Detected mode change from
SCSI to RAID on ChB of the embedded RAID system.”

8. Select

Yes

.

The K2 Media Server restarts as normal.

When startup completes, normal operation is restored.