Replacing a disk module – Grass Valley K2 Storage System Instruction Manual v.3.2 Aug.01 2007 User Manual

Page 383

Advertising
background image

July 3, 2007

K2 Storage System Instruction Manual

383

Replacing a disk module

To determine your disk drive type and current firmware version, select a disk drive
icon in the Storage Utility tree view, then note the drive properties reported in the
right-hand pane. Use the following procedure if you need to download disk drive
firmware.

NOTE: The disk drives on each controller are upgraded one at a time which can
take as long as 2 minutes per drive. Take this into consideration when scheduling
the upgrade.

Requirements for this procedure are as follows:

• All K2 Media Clients and other clients must be powered down, or in some other

way disconnected from the K2 Storage System.

• The K2 Media Server through which Storage Utility is connected to the RAID

Storage must be powered up.

• All other K2 Media Servers must be powered down.

To download disk drive firmware, do the following:

1. Refer to K2 Storage System Release Notes to determine firmware types, versions,

files, and any other special instructions regarding the particular disk drive firmware
you are downloading.

2. In the Storage Utility, right-click a controller in the tree view, then select

Advanced

| Download Disk Firmware

in the context menu. The Open File dialog box opens.

NOTE: You can download firmware to a single disk by right-clicking a disk icon in
the tree view.

3. In the Open File dialog box, browse to the latest firmware file for your disks, select

the file, and click.

4. Click

OK.

As instructed by a message that appears, watch the lights on the drives. For each
drive, one at a time, the lights flash as firmware loads. Wait until the lights on all
the drives on which you are downloading firmware have completed their flashing
pattern. This can take several minutes.

The Progress Report window appears showing the disk firmware download task
and the percentage complete.

5. When finished, restart the RAID storage and the K2 Media Server.

Replacing a disk module

In the event of a disk drive failure, you’ll repair the system by replacing the disk
module as soon as possible. Refer to the Instruction Manual for your level of RAID
storage chassis for information on removing and replacing disk modules.

NOTE: Always use Storage Utility to physically identify the failed disk module.
Accidently removing the wrong disk module can destroy all media on the disk
drives.