Chapter 2 Installing the Level 2 Storage System

common mistake is to attempt a transfer in which the source/destination is
incorrectly specified as the K2 Media Client. The host file aliasing corrects this
mistake and redirects to the K2 Media Server, which is the correct transfer source/
destination.

An example of a hosts file entry with this type of aliasing is as follows:

192.168.101.11

server_1_he0 client_1_he0 client_2_he0

Testing the control network

To test the control network use the ping command as follows:

1. On the control point PC, click

Start | Run

. The Run dialog box opens.

2. Type cmd and click

OK

. The command prompt window opens.

3. Type ping, then a space, then the name of one of your K2 Storage System devices,

such as the Gigabit Ethernet switch, as in the following example:

ping root_gige_1

4. Press

Enter

.

The ping command should return the IP address of the device, as in the following
example:

Pinging root_gige_1.mycorp.com [192.168.100.61] with
32 bytes of data:

Reply from 192.168.100.61: bytes=32 time=10ms TTL=127

Reply from 192.168.100.61: bytes=32 time<10ms TTL=127

Reply from 192.168.100.61: bytes=32 time<10ms TTL=127

Reply from 192.168.100.61: bytes=32 time<10ms TTL=127

This verifies that the name of the device is being correctly resolved to the IP
address, which indicates that on the Control Point PC the host table entry is correct.

5. Ping the other K2 Storage System devices to which you have assigned control

network IP addresses.

6. Go to each Windows device in the K2 Storage System and repeat this procedure.

This verifies that network communication is correct to and from all devices.