Configuring the nearline storage system, Prerequisites for initial configuration – Grass Valley K2 Storage System Instruction Manual v.3.2 Aug.01 2007 User Manual

Page 260

Advertising
background image

260

K2 Storage System Instruction Manual

July 3, 2007

Chapter 6 Installing the Nearline Storage System

Configuring the nearline storage system

Use the topics in this section to do the initial configuration of the nearline storage
system.

“Prerequisites for initial configuration” on page 260

“Defining a new K2 Storage System” on page 261

“Configuring the server - Part 1” on page 263

“Configuring RAID” on page 265

“Creating a new file system” on page 272

“Configuring the server - Part 2” on page 273

“Configuring remaining servers” on page 275

Prerequisites for initial configuration

Before beginning your initial configuration, make sure the devices of the K2 Storage
System meet the following prerequisites. Refer to sections earlier in this manual for
detailed information. Also refer to

Chapter 7, “Description of K2 Storage Devices”

.

Devices

Prerequisite for nearline configuration

Control point PC

Ethernet cable connected
Control Point software installed
Control network IP address assigned
Network communication over the control network with all other K2
devices
Power on

Ethernet switch

Ethernet cables connected
Control network IP address assigned
Power on

K2 Media Server

Ethernet cables connected
Fibre Channel cable connected
Software installed, as from the factory, including QuickTime 7
Control network IP address assigned
Power on for all servers

L3 RAID chassis

Fibre Channel address ID assigned to RAID controller(s)
Fibre Channel cable(s) connected
Ethernet cable(s) connected
Power on

L3 RAID Expansion
chassis

Chassis address assigned (for Fibre Channel)
Fibre channel cable(s) connected
Power on

Advertising