Grass Valley K2 Storage System Instruction Manual v.3.2 Aug.01 2007 User Manual

Page 235

Advertising
background image

July 3, 2007

K2 Storage System Instruction Manual

235

K2 Media Server failover with Control team failover behavior

If the following system component fails to respond to system communication:

• The “A” GigE switch

Then the following failover behavior occurs:

1. The media file system (SNFS) and media database (SQL) on K2 Media Server “A”

fail over and K2 Media Server “B” becomes the active media file system/database
server.

2. All K2 Media Clients drop communication on the “A” media port and begin using

the “B” media port, finding a path through GigE switch “B” to K2 Media Server
“B”. All K2 Media Clients use an iSCSI adapter (TOE) on the “B” K2 Media
Server to provide access to the Fibre Channel connected RAID storage.

3. For all K2 Media Clients, communication fails on the control port, so the control

team fails over and communication begins on the other control port.

4. For all K2 Media Clients, control communication finds a path through GigE switch

“B” to K2 Media Server “B”.

L2R RAID chassis

K2 Media
Servers

K2 Media
Clients

Gigabit
Ethernet
switches

A

A

B

B

Fibre Channel
connections

Control

Media

Control

Media

Control

FTP

Media

POWER

SERVICE

K2

RAID STORAGE

!

!

!

!

!

Media

Control

FTP

Media

Media

ISLs

X

Component
Failure

Advertising