Setting up the k2 media server – Grass Valley K2 Storage System Instruction Manual v.3.2 Aug.01 2007 User Manual

Page 249

Advertising
background image

July 3, 2007

K2 Storage System Instruction Manual

249

Setting up the K2 Media Server

Dell 2850 PowerEdge server

Dell 2950 PowerEdge server

Do not connect the iSCSI ports. They are not used for the Nearline storage
system.

Connect the motherboard GigE port 1 and GigE port 2 to control ports on the
GigE switch.

Connect one of the Fibre Channel ports to the RAID storage device.

• Assign a control network IP address to GigE port 1. Use standard Windows

procedures. Refer to

“Networking tips” on page 56

.

• Change the hostname. Use standard Windows procedures.

• Configure SNMP properties so the trap destination points to the NetCentral server

PC. Use standard Windows procedures. If you are not using the SNMP community
name “public”, configure the community name and set permissions to RW. Also
make sure that the Authentication trap is enabled.

Also refer to

“K2 Media Server description” on page 287

.

3

2

1

iSCSI interface

Power

Keyboard/Mouse

GigE

Fibre Channel

VGA monitor

GigE

(FTP) (control)

ports

port 1

(USB)

Serial port

port 2

(not used)

PCI 1

PCI 2

PCI 3

Serial port

VGA monitor

Fibre Channel

Power supply

Power supply

Keyboard/Mouse
(USB)

GigE
port 2
(FTP)

GigE
port 1
(control)

iSCSI
interface
ports
(not used)

Advertising