Setting up the Nearline GigE switches

b. Click

Modify Selected Ports

.

c. For the trunked ports, set Port Enabled to

Yes

. On some switch models, the 10

Gig ISL ports are disabled by default, so make sure you enable them. Leave
Mode as default of

Auto

.

d. Set Flow Control as follows:

- For the 3400cl series switch, set to

Disable

.

- For the 2900 series switch, set to

Enable

.

If you have both 3400cl series and 2900 series on your network, having different
Flow Control settings (disable for 3400cl, enable for 2900) does not cause
problems.

e. Click

Apply Settings

.

8. On the Port Configuration page, do one of the following:

• If you do not have trunks, select all ports.

• If you have trunks, select the remaining ports (the ports not trunked).

This setting
varies depending
on switch model.
Set as instructed
in text.