K2 Storage System Instruction Manual

July 3, 2007

Chapter 5 Installing the Level 3R Storage System

Configuring the redundant server 2B

You must wait for server 2A to restart before continuing.

For Level 3 redundant, the last K2 Media Server to configure is server 2B. It is the
redundant partner to server 2A.

iSCSI Bridge Server
Configuration

This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
RAID storage. You
configure network settings
on the iSCSI adapter and the
page validates that the media
LUNs are visible as iSCSI
targets.

For Level 3 redundant, select

Primary

.

Select an iSCSI adapter and click

Modify

. A network configuration

dialog box opens. Enter the media network IP address and subnet mask
and click

Apply

. Do the same for the other iSCSI adapter.

To verify drives, click

Check

then

View Target Drives

. You should see

all your media drives listed.
Click

Next

.

FTP Server Configuration

Do not modify these settings. Leave at default values of Max FTP
streams = 4 and FTP Data Socket Timeout = 60. Only qualified Grass
Valley personnel should specify other values, as these settings are
intended for use only with custom systems designed by Grass Valley.
Click

Next

Completing the
Configuration Wizard

Click

Finish

. The wizard closes. The K2 Media Server restarts. Do not

proceed until restart processes are finished. If you are not sure if startup
is complete, wait 10 minutes.