Chapter 3 Installing the Level 2R Storage System

Make a direct connection between the serial ports of the two servers.

Take care to use the proper serial cable to interconnect redundant K2 Media
Servers that take the role of file system/database servers. This cable supports the
heartbeat mechanism whereby the servers monitor each other’s health. It is a 9
pin serial cable, but it is not a standard RS-232 null modem cable. The heartbeat
cable is supplied with your system (Grass Valley part number 174-8137-00) and
has a pin configuration as follows:

1 – 4

2 – 3

3 – 2

4 – 1&6

5 – 5

6 – 4

7 – 8

8 – 7

9 – No Connect

• Assign a control network IP address to GigE port 1. Use standard Windows

procedures. Refer to

“Networking tips” on page 56

.

• Change the hostname. Use standard Windows procedures.

• Configure SNMP properties so the trap destination points to the NetCentral server

PC. Use standard Windows procedures. If you are not using the SNMP community
name “public”, configure the community name and set permissions to RW. Also
make sure that the Authentication trap is enabled.

Also refer to

“K2 Media Server description” on page 287

.

Setting up the L2 RAID chassis

Do the following to prepare the L2 RAID storage devices:

• Install the chassis in its permanent location. Refer to the L2 RAID Instruction

Manual for rack mount instructions.

“Assign Fibre Channel address ID” on page 85

.

“Connect the L2 RAID chassis” on page 85

“Assign chassis address on Expansion chassis” on page 86

.

“Power on the L2 RAID chassis” on page 88

In addition, you will configure network settings, SNMP settings, and bind LUNs.
These tasks are part of the K2 System Configuration application and Storage Utility
procedures later in this chapter. The process of binding LUNs can take a significant
amount of time—as much as eight hours—so you might want to put priority on the
tasks necessary to start the LUN binding process, then catch up with other tasks while
the LUNs are binding.

Also refer to

“K2 Level 2 RAID storage description” on page 290

.