K2 Storage System Instruction Manual

241

Setting up the Nearline GigE switches

• Install the switches in their permanent location.

• Provide power to the switches.

3400cl series switch

2900 series switch

NOTE: If the switch is used for the Nearline system only and there is no K2 media
(real-time iSCSI) traffic on the switch, there is no need for VLANs or dedicated
“media” ports.

If you have one switch for the Nearline system, connect as follows:

• Make two connections (control and FTP) from each K2 Media Server, one

connection from each RAID controller, and one connection from the control
point PC.

If you have two switches for the Nearline system, connect as follows:

• To the ports on switch A, make a connection from RAID controller 0 and from

the control point PC. Also make two connections (control and FTP) from half of
the installed Nearline K2 Media Servers.

• To the ports on switch B, make a connection from RAID controller 1, if it is

installed. Also make two connections (control and FTP) from the remaining
Nearline K2 Media Servers.

Refer to

“Nearline system description” on page 238

for a diagram of the complete

system.

Refer to cabling procedures later in this chapter for the GigE connections at each of
the devices of the K2 Storage System.

Also refer to

“K2 Ethernet switch description” on page 285

and

“Design

considerations for Ethernet switches” on page 388

.

Media Ports

Control Ports

1 - 19 odd

2 - 20 even

Media Ports

Control Ports

1 - 19 odd

2 - 20 even