background image

M

ODEL

N

UMBER

N

OMENCLATURE

- 25 D

IGIT

C

ONFIGURATION

N

UMBER

Model # Part 1 *

Model Details

Model # Part 2 *

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

C

R

0

2

0

R

A

1

C

7

S

D

1

8

1

1

E

L

1

0

P

A

*

*

*

Digits 1-2 - Unit Family

Digit 17 - High-Voltage Options

Liebert

®

CRV

= CR

L or A = NO dual-float condensate pump (for units without

humidifier), 5kA SCCR**

Digits 3-5 - Nominal Capacity, kW

DX = 020, 035

5 or E = Dual-float condensate pump (for units with or

without humidifier), 5kA SCCR**

CW = 040

Digit 6

M = No dual-float condensate pump (for units without

humidifier), 65kA SCCR, 600 series only

R = Row-Based, 1100mm unit depth

Digit 7 - System Type

P = Dual-float condensate Pump (for units with or without

humidifier), 65kA SCCR, 600 series only

A = Air Cooled
W = Water\Glycol Cooled

Digit 18 - Option Package

C = Chilled Water Cooled

0 = None

Digit 8 - Fan Type

H = Reheat and Humidifier Lockout

Variable Speed EC Plug Fans = 1

C = Reheat and Humidifier Lockout Additional Alarm

Contact

Digit 9 - Power Supply

A = 460V / 3ph / 60Hz

D = Low Sound Package (20kW and 35kW only)

C = 208V / 3ph / 60Hz

L = Low Sound Package & Reheat and Humidifier Lockout

and Additional Alarm Contact (20kW and 35kW only)

Digit 10 - Cooling System

2 = Two-Way Valve (CW Only)

Digit 19 - Liebert IntelliSlot

®

Housing

3 = Three-Way Valve (CW Only)

0 = No Cards

7 = R-410A Digital Scroll Single Circuit (DX Only)

1 = (1) Web Card

Digit 11 - Humidifier

2 = (2) Web Cards

0 = None

3 = (1) 485 Card

S = Steam Generating Canister

4 = (2) 485 Cards

Digit 12 - Display Type

5 = (1) Web Card and (1) 485 Card

D = Liebert iCOM Control with Large Graphic Display

C = (1) Liebert SiteLink-E Card

Digit 13 - Reheat

D = (1) Liebert SiteLink-E Card and (1) Web Card

0 = None

E = (1) Liebert SiteLink-E Card and (1) IS-485 Card

1 = Electric Reheat

F = (1) Building Management Card

Digit 14 - Air Filter

G = (2) Building Management Cards

8 = 4" MERV 8 + Clogged Filter Alarm

H = (1) Building Management Card and (1) Web Card

9 = 4" MERV 11 + Clogged Filter Alarm

J = (1) Building Management Card and (1) IS-485 Card

Digit 15 - Water/Glycol Valve Type

K = (1) Building Management Card and (1) Liebert

SiteLink-E Card

1 = Two-Way Valve (W/G only) OR

Default Air-Cooled Selection

Digit 20 - Future Options

7 = Three-Way Valve (W/G only)

0 = None

H = Default CW Selection

Digit 21 - Packaging

Digit 16 - Unit Color

P = Domestic

1 = Standard Color (Z-7021 Black)

S = Export (Seaworthy)

2 = Non-Standard Color

Digit 22 - Special Features

A = No SFAs, Standard Unit
X = SFA Included

Digits 23-25 - Factory Configuration Number