Table 40: EN50178 fuses 200 V to 480 V

Frequency converter

Maximum fuse size

Voltage

Type

208–230 V — T2
0015–0020

16A

1)

200–240

type gG

0030

25A

1)

200–240

type gG

0050

35A

1)

200–240

type gG

0075

50A

1)

200–240

type gG

0100

63A

1)

200–240

type gG

0150

63A

1)

200–240

type gG

0200

80A

1)

200–240

type gG

0250

125A

1)

200–240

type gG

0300

125A

1)

200–240

type gG

0400

160A

1)

200–240

type gG

0500

200A

1)

200–240

type aR

0600

250A

1)

200–240

type aR

380–460 V — T4
0015–0020

10A

1)

380–500

type gG

0030

16A

1)

380–500

type gG

0050–0075

25A

1)

380–500

type gG

0100

35A

1)

380–500

type gG

0150–0200

63A

1)

380–500

type gG

0250

63A

1)

380–500

type gG

0300

63A

1)

380–500

type gG

0400

80A

1)

380–500

type gG

0500

100A

1)

380–500

type gG

0600

125A

1)

380–500

type gG

0750

160A

1)

380–500

type gG

1000

250A

1)

380–500

type aR

1250

250A

1)

380–500

type aR

1)

Maximum fuses see national/international regulations for selecting an applicable fuse

size.

Table 41: 525–690 V, Frame sizes A, C, D, E and F (non-UL fuses)

Enclosure size

Power [HP]

Current rating

Recommended

fuse size

Recommended

maximum fuse

Recommended

circuit breaker

Danfoss

Maximum trip

level [A]

A3

1.5

gG-6

gG-25

CTI25M 10–16

16

2

gG-6

gG-25

CTI25M 10–16

16

3

gG-6

gG-25

CTI25M 10–16

16

5

gG-10

gG-25

CTI25M 10–16

16

7.5

gG-16

gG-25

CTI25M 10–16

16

10

gG-16

gG-25

CTI25M 10–16

16

Technical Specification