Technical specification aquavar, Intelligent pump controller instruction manual 141 – Xylem IM255 AQUAVAR Intelligent Pump Controller User Manual

Page 143

Advertising
background image

16-22

T

orque

[%]

16-26

Power

Filtered

[kW]

16-27

Power

Filtered

[hp]

16-3*

Drive

Status

16-30

DC Li

nk V

oltage

16-32

Brake Energy

/s

16-33

Brake Energy

/2

min

16-34

Hea

tsi

nk T

emp.

16-35

Inverter Thermal

16-36

Inv

. Nom. Current

16-37

Inv

. Max.

Current

16-38

SL Controller

State

16-39

Con

tro

l Card T

emp.

16-40

Log

ging Buf

fer Full

16-41

Log

ging Buf

fer Full

16-43

T

imed Actions Status

16-49

Current

Fault

Source

16-5*

Ref. & Feedb.

16-50

External

Reference

16-52

Feedback[Unit]

16-53

Digi

Pot

Reference

16-54

Feedback

1 [Unit]

16-55

Feedback

2 [Unit]

16-56

Feedback

3 [Unit]

16-58

PID Output [%]

16-6*

Inputs

&

Outputs

16-60

Digital

Input

16-61

T

erminal

53 Switch Setting

16-62

Analog

Input 53

16-63

T

erminal

54 Switch Setting

16-64

Analog

Input 54

16-65

Analog

Output 42 [mA]

16-66

Digital

Output [bin]

16-67

Pulse

Input

#29

[Hz]

16-68

Pulse

Input

#33

[Hz]

16-69

Pulse

Output #27

[Hz]

16-70

Pulse

Output #29

[Hz]

16-71

Relay

Output

[bin]

16-72

Counter

A

16-73

Counter

B

16-75

Anal

og In X30/1

1

16-76

Analog

In X30/12

16-77

Analog

Out

X30/8

[mA]

16-8*

Fieldbus

& FC Port

16-80

Fieldbus

CTW

1

16-82

Fieldbus

REF 1

16-84

Comm. Option STW

16-85

FC Port CTW

1

16-86

FC Port REF 1

16-9*

Diagnosis Readouts

16-90

Alarm W

ord

16-91

Alarm W

ord 2

16-92

W

arnin

g

W

ord

16-93

W

arnin

g

W

ord

2

16-94

Ext. St

at

us

W

ord

16-95

Ext. St

at

us

W

ord

2

16-96

Main

te

nance W

ord

18-**

Info

&

Readouts

18-0*

Maintenance Log

18-00

Maintenance

Log: Item

18-01

Maintenance

Log: Action

18-02

Main

te

nance Log: T

ime

18-03

Main

te

nance Log: Date an

d T

ime

18-1*

Fire Mode Log

18-10

FireMode

Log:Event

18-1

1

Fire Mode

L

og: T

ime

18-12

Fire Mode

L

og: Date and T

ime

18-3*

Inputs

&

Outputs

18-30

Analog

Input X42/1

18-31

Analog

Input X42/3

18-32

Analog

Input X42/5

18-33

Analog

Out

X42/7

[V]

18-34

Analog

Out

X42/9

[V]

18-35

Anal

og Out

X4

2/1

1

[V]

18-36

Analog

Input X48/2 [mA]

18-37

T

emp. Input X48/4

18-38

T

emp. Input X48/7

18-39

T

emp. Input X48/10

18-5*

Ref. & Feedb.

18-50

Sensorless

Readout [unit]

20-**

Drive

Closed Loop

20-0*

Feedback

20-00

Feedback

1 Source

20-01

Feedback

1 Conversion

20-02

Feedback

1 Source Unit

20-03

Feedback

2 Source

20-04

Feedback

2 Conversion

20-05

Feedback

2 Source Unit

20-06

Feedback

3 Source

20-07

Feedback

3 Conversion

20-08

Feedback

3 Source Unit

20-12

Reference/Feedback

Unit

20-13

Minimum

Reference/Feedb.

20-14

Maximum

Reference/Feedb.

20-2*

Feedback/Setpoint

20-20

Feedback

Function

20-21

Setpoint

1

20-22

Setpoint

2

20-23

Setpoint

3

20-3*

Feedb. Adv

. Conv

.

20-30

Refrigerant

20-31

User Defined

Refrigerant

A1

20-32

User Defined

Refrigerant

A2

20-33

User Defined

Refrigerant

A3

20-34

Duct 1 Area [m2]

20-35

Duct 1 Area [in2]

20-36

Duct 2 Area [m2]

20-37

Duct 2 Area [in2]

20-38

Air Density

Factor [%]

20-6*

Sensorless

20-60

Sensorless

Unit

20-69

Sensorless

Information

20-7*

PID Autotuning

20-70

Clo

sed Loop T

ype

20-71

PID Performance

20-72

PID Output Change

20-73

Minimum

Feedback Level

20-74

Maximum

Feedback

Level

20-79

PID Autotuning

20-8*

PID Basic Settings

20-81

PID Normal/ Inverse

Control

20-82

PID Start Speed [RPM]

20-83

PID Start Speed [Hz]

20-84

On Reference

Bandwidth

20-9*

PID Controller

20-91

PID Anti Windup

20-93

PID Proportional

Gain

20-94

PID Integral T

ime

20-95

PID Dif

ferentiatio

n T

ime

20-96

PID Dif

f. Gain Limit

21-**

Ext. Closed Loop

21-0*

Ext. CL Autotuning

21-00

Clo

sed Loop T

ype

21-01

PID Performance

21-02

PID Output Change

21-03

Minimum

Feedback Level

21-04

Maximum

Feedback

Level

21-09

PID Autotuning

21-1*

Ext. CL 1 Ref./Fb.

21-10

Ext. 1 Ref./Feedback Unit

21-1

1

Ext. 1 Minimum Reference

21-12

Ext. 1 Maximum Reference

21-13

Ext. 1 Reference Source

21-14

Ext. 1 Feedback Source

21-15

Ext. 1 Setpoint

21-17

Ext. 1 Reference [Unit]

21-18

Ext. 1 Feedback [Unit]

21-19

Ext. 1 Output

[%]

21-2*

Ext. CL 1 PID

21-20

Ext. 1 Normal/Inverse Control

21-21

Ext. 1 Proportional

Gain

21-22

Ext. 1 I

nt

egral T

ime

21-23

Ext. 1 Dif

fe

rentation T

ime

21-24

Ext. 1 Dif.

Gain

Limit

21-3*

Ext. CL 2 Ref./Fb.

21-30

Ext. 2 Ref./Feedback Unit

21-31

Ext. 2 Minimum Reference

21-32

Ext. 2 Maximum Reference

21-33

Ext. 2 Reference Source

21-34

Ext. 2 Feedback Source

21-35

Ext. 2 Setpoint

21-37

Ext. 2 Reference [Unit]

21-38

Ext. 2 Feedback [Unit]

21-39

Ext. 2 Output

[%]

21-4*

Ext. CL 2 PID

21-40

Ext. 2 Normal/Inverse Control

21-41

Ext. 2 Proportional

Gain

21-42

Ext. 2 I

nt

eg

ral T

ime

21-43

Ext. 2 Dif

fe

rentation T

ime

21-44

Ext. 2 Dif.

Gain

Limit

21-5*

Ext. CL 3 Ref./Fb.

21-50

Ext. 3 Ref./Feedback Unit

21-51

Ext. 3 Minimum Reference

21-52

Ext. 3 Maximum Reference

21-53

Ext. 3 Reference Source

21-54

Ext. 3 Feedback Source

21-55

Ext. 3 Setpoint

21-57

Ext. 3 Reference [Unit]

21-58

Ext. 3 Feedback [Unit]

21-59

Ext. 3 Output

[%]

21-6*

Ext. CL 3 PID

21-60

Ext. 3 Normal/Inverse Control

21-61

Ext. 3 Proportional

Gain

21-62

Ext. 3 I

nteg

ral T

ime

21-63

Ext. 3 Dif

fe

rentation T

ime

21-64

Ext. 3 Dif.

Gain

Limit

22-**

Appl.

Functions

22-0*

Miscellaneous

22-00

Pump Protect Delay

22-01

Power

Fil

ter

T

ime

22-2*

No-Flow

Detection

22-20

Low

Power

Auto Set-up

22-21

Low

Power

Detection

22-22

Low

Speed

Detection

22-23

No-Flow

Function

22-24

Sleep

Delay

22-26

No W

ater/Loss of Prime Function

22-27

No W

ater/Loss of Prime Delay

22-3*

No-Flow

Power T

uning

22-30

No-Flow

Power

22-31

Power Correction

Factor

22-32

Sleep

Frequency

[RPM]

22-33

Sleep

Frequency

[Hz]

22-34

Low Speed

Power [kW]

22-35

Low Speed

Power [HP]

22-36

High

Speed

[RPM]

22-37

High

Speed

[Hz]

22-38

No W

ater/Loss of Prime Limit [kW]

22-39

No W

ater/Loss of Prime Limit [HP]

22-4*

Sleep Mode

22-40

Mini

mum Run T

ime

22-41

Mini

mum S

leep T

ime

22-42

W

ake-up Speed

[RPM]

22-43

W

ake-up Speed

[Hz]

22-44

Restart Dif

ference

22-45

Setpoint Boost

22-46

Maximum Boo

st

T

ime

22-5*

Under Pressure

22-50

Under

Pressure

Function

22-51

Under

Pressure

Delay

22-52

Unde

r

Pre

ssure Dif

ference

22-6*

Broken Belt Detection

22-60

Broken Belt Function

22-61

Broken Bel

t T

orque

22-62

Broken Belt Delay

22-7*

Short Cycle Protection

22-75

Short Cycle Protection

22-76

Interval between

Starts

22-77

Minimu

m

R

un T

ime

22-78

Minimu

m

R

un T

ime Override

22-79

Minimu

m

R

un T

ime Override V

alue

22-8*

Flow

Compensation

22-80

Flow Compensation

22-81

Square-linear

Curve

Approximation

22-82

W

ork Point Calculation

22-83

Speed

at No-Flow

[RPM]

22-84

Speed

at No-Flow

[Hz]

22-85

Speed

at Design

Point [RPM]

22-86

Speed

at Design

Point [Hz]

22-87

Pressure at No-Flow

Speed

22-88

Pressure at Rated

Speed

22-89

Flow at Design

Point

22-90

Flow at Rated Speed

23-**

T

ime-based Functions

23-0*

T

imed Actions

23-00

ON T

ime

23-01

ON Action

23-02

OFF

T

ime

23-03

OFF

Action

23-04

Occurrence

23-0*

T

imed Actions

Settings

23-08

T

imed Actions Mode

23-09

T

imed Actions Reactivation

23-1*

Maintenance

23-10

Maintenance

Item

23-1

1

Maintenance

Action

23-12

Mainten

ance T

ime Base

23-13

Mainten

ance T

ime Interval

23-14

Mainten

ance Date and T

ime

23-1*

Maintenance Reset

23-15

Reset Main

te

nance W

ord

23-16

Mainten

ance T

ext

23-5*

Energy Log

23-50

Energy Log

Resolution

23-51

Period

Start

23-53

Energy Log

23-54

Reset Energy

Log

23-6*

Trending

23-60

T

rend V

ariable

23-61

Continuous

Bin Data

23-62

T

imed Bin Data

23-63

T

imed Period

Start

23-64

T

imed Period

Stop

23-65

Minimu

m

Bi

n V

alue

23-66

Reset Continuous

Bin Data

23-67

Reset T

imed Bin Data

23-8*

Payback

Counter

23-80

Power Reference

Factor

23-81

Energy Cost

23-82

Investment

23-83

Energy Savings

23-84

Cost Savings

24-**

Appl.

Functions

2

24-0*

Fire Mode

24-00

Fire Mode Function

24-01

Fire Mode Configuration

24-02

Fire Mode Unit

24-03

Fire Mode Min

Reference

24-04

Fire Mode Max Reference

24-05

Fire Mode Preset Reference

24-06

Fire Mode Reference

Source

24-07

Fire Mode Feedback

Source

24-09

Fire Mode Alarm

Handling

24-1*

Drive Bypass

24-10

Drive Bypass

Function

Technical Specification

Aquavar

®

Intelligent Pump Controller INSTRUCTION MANUAL

141

Advertising