PRECAUTIONS

The Model DY Vortex Flowmeter and Model DYA
Vortex Flow Converter are thoroughly tested at the
factory before shipment. When these instruments
are delivered, perform a visual check to ascertain
that no damage occurred during shipment.
This section describes important cautions in
handling these instruments. Read carefully before
using them.
If you have any problems or questions, contact
your nearest YOKOGAWA service center or sales
representative.

2.1 Checking Model and

Specifi cations

The model and important specifi cations are
indicated on the name plate attached to the case.
Verify that they are the same as those specifi ed in
the original order, refer to Chapter 13 “GENERAL
SPECIFICATIONS .” In any correspondence,
always give model (MODEL) and serial number
(NO.) from the name plate.

F0201.ai

TAG NO.

4 ~ 20mA DC / PULSE

MPa at 38°C

10.5 ~ 42V DC

3UA

3UA

*1)

*2)

Figure 2.1(a) Example of Name Plate for Integral Type

F0202.ai

TAG NO.

4 ~ 20mA DC / PULSE

3YA

TAG NO.

3WA

10.5 ~ 42V DC

MPa at 38°C

*1)

*1)

*2)

*2)

Figure 2.1(b) Example of Name Plate for Remote Type

*1): K factor at + 15°C
*2): The product - producing country.

2.2 Transportation and Storage

Precautions

If the instrument is to be stored for a long period of
time after delivery, observe the following points.

(1) The instrument should be stored in its original

packing condition in the storage location.

(2) Select a storage location that fulfi ls the following

conditions:

• A place where it will not be exposed to rain or

water

• A place subject to minimal vibrations or shocks
• Temperature and humidity levels should be as

follows:

Temperature:-40 to +80°C

Humidity:5 to 100% RH (no condensation)

The preferred ambient temperature and

humidity levels are +25°C and approximately
65% RH.

(3) If the digitalYEWFLO vortex fl owmeter is

transferred to the installation site and stored
without being installed, its performance may
be impaired due to the infi ltration of rainwater
and so forth. Be sure to install and wire the
digitalYEWFLO vortex fl owmeter as soon as
possible after transferring it to the installation
location.

(4) The vortex fl owmeter is a heavy instrument. Be

careful that no damage is caused to personnel
through accidentally dropping it, or by exerting
excessive force on the vortex fl owmeter. When
moving the vortex fl owmeter, always use a
trolley and have at least two people carry it.