<13. GENERAL SPECIFICATIONS>

13-3

IM 01F06A00-01EN

Status Output Function*:

Flow Switch:
In case fl ow rate decreases under the fl ow set
value,a status signal is output.
Status signal output mode can reverse (ON/
OFF).

Data Security During Power Failure:

Data (parameter, totalizer value, etc) storage
by EEPROM. No back-up battery required.

Correction:

Instrument Error Correction:
Vortex fl owmeter instrument errors can be
corrected by segment approximations.
Reynolds Number Correction:
Output error at Reynolds number 20000 or
less is corrected by using fi ve-break-point line-
segment approximation.
Gas Expansion Correction:
When measuring a compressibility gas and
steam, this expansion factor is useful to
correct the error at high velocity of fl ow (35m/s
or more).

Down-scale or Up-scale burn out.

In case a CPU or EEPROM failure occurs,
fl ow meter output the signal of Up-scale (21.6
mA or more).
Up-scale or Down-scale (3.6 mA or less) is
user-selectable through the fail mode alarm
jumper.

Indicator:

Flow rate (% or engineering units) or tem-
perature value and totalizer can be indicated
simultaneously.
Short message for self diagnostics indicated.
Local parameter setting can be operated by
key switches.
In mounting direction, the right and left 90° is
rotatable.

EMC Conformity Standards:

EN 61326-1: 2006 Class A, Table 2 (For use in
industrial locations), EN 61326-2-3: 2006

Note1: This instrument is a Class A product, and it is

designed for use in the industrial environment.
Please use this instrument in the industrial
environment only.

Note2: Use the metal conduit for the remote cable.

Pressure Equipment Directive:

Type of equipment: piping
Type of fl uid: liquid and gas
Group of fl uid: 1 and 2
Assessment: Module H

MODEL

DN(mm)* PS(MPa)* PS·DN(MPa·mm) CATEGORY**

DY015

15

42

630

Article 3,***

Paragraph 3

DY025

25

42

1050

Article 3,***

Paragraph 3

DY040

40

42

1680

II

DY050

50

42

2100

II

DY080

80

42

3360

II

DY100

100

42

4200

II

DY150

150

42

6300

III

DY200

200

42

8400

III

DY250

250

42

10500

III

DY300

300

42

12600

III

DY400

400

25

10000

III

*

PS: Maximum allowable pressure for Flow tube, DN: Nominal
size

**

Refered to Table 6 coverd by ANNEX II of EC Directive on
Pressure Equipment Directive 97/23/EC

*** DY015 and DY025 are not regulated by PED.

200

100

50

0

-50

-29

100

50

0

300

3URFHVV7HPSHUDWXUH Û&

With Indicator

$PELHQW7HPSHUDWXUH Û&

Without Indicator

85

-50

250

85

-29

80

80

F1301.ai

55

Figure 13.1

Ambient Temperature limit (Integal Type)