General specifications, 1 standard specifications, General – Yokogawa digitalYEWFLO (DY) User Manual

Page 111: Specifications, 1 standard, Specifi cations -1, 1 standard specifi cations

Advertising
background image

<13. GENERAL SPECIFICATIONS>

13-1

IM 01F06A00-01EN

13. GENERAL

SPECIFICATIONS

13.1 Standard Specifi cations

 Communication function includes F

OUNDATION

fi eldbus, BRAIN and HART protocol.

Refer to GS 01F06F01-01EN for Fieldbus

communication type marked with “”.

Performance Specifi cations

Fluid to be Measured:

Liquid, Gas, Steam (Avoid multiphase fl ow
and sticky fl uids)

Measuring Flow Rates:

Refer to Table 13.6

Accuracy: ±0.75% of Reading (Liquid)

±1% of Reading (Gas, Steam)

Refer to Section 13.5 “Detailed Accuracy.”

/MV: Refer to Subsection 13.3.1 “Option
Multi-Variable (Built-In Temperature
Sensor) Type (/MV).”

Repeatability: ± 0.2% of Reading
Calibration:

This fl owmeter is factory-calibrated using a
water fl ow.

Temperature and fl ow calibration by water
fl ow when Multi-Variable Type is selected.

Normal Operating Condition

Process Temperature Range:

–29 to +250 °C (Standard)

–196 to +100 °C (Cryogenic Version:

Option)

–29 to +450 °C (High Process Temperature

Version: Option)

–29 to +400 °C (High Process Temperature

Version Multi-Variable
Type: Option)

When Multi-Variable Type is selected, refer
to Subsection 13.3.1 “Option Multi-Variable
(Built-In Temperature Sensor) Type (/MV).”

Refer to Figure 13.1 for integral type.

Process Pressure Limit:

–0.1MPa (–1 kg/cm

2

) to fl ange rating.

Ambient Temperature Range:

–29 to +85 °C (Remote Type detector)

–40 to +85 °C (Remote Type converter)

–29 to +85 °C (Integral Type, refer to Figure

13.1)

–29 to +80 °C (Integral Type with Indicator,

refer to Figure 13.1)

–30 to +80 °C (Remote Type converter with

Indicator)

Ambient Humidity: 5 to 100% RH (at 40 °C)

(No Condensation)

Power Supply Voltage (): 10.5 to 42 V DC

10.5 to 30 V DC (Lightning Protector: option)

(Refer to Figure 13.2 ; Relationship
Between Power Supply Voltage and Load
Resistance)

Mechanical Specifi cations

Material (Standard Type):

Refer to Table.13.1
Wetted Parts:

Body*

1

; Stainless steel JIS SCS14A,

ASTM CF8M

*1 Flange materials for DY250 to DY400 are

JIS SUS F304

Shedder Bar; Duplex stainless steel

Size 15mm ASTM S31803
Size 25mm to 400mm EN 1.4517

Gasket: JIS SUS316 stainless steel with

polytetrafl uoroethylene (Tefl on)
coating.

Non-Wetted Parts:

Housing (Case, Cover):

Aluminum alloy JIS ADC12

Name Plate: Stainless steel JIS SUS304
DYA Mounting Bracket for 2B pipe:

Carbon steel sheet JIS SPCC, JIS SECC

Coating Color:

Housing:

Polyurethane corrosion-resistant coating
Deep sea moss green (Munsell 0.6GY 3.1/2.0)

DYA Mounting Bracket for 2B pipe:

Polyurethane corrosion-resistant coating
Frosty white (Munsell 2.5Y 8.4/1.2)

Protection:

IP67, Type 4X, JIS C 0920 watertight protection.

Hazardous Area Classifi cations:

Refer to Section 13.3 “Option Specifi cations”.

Electrical Connection:

JIS G1/2 female, ANSI 1/2 NPT female,
ISO M20 × 1.5 female

Signal Cable:

Model DYC signal cable, used for remote
detector and converter.
Signal cable length is up to 30 m.
Outer Sheath Material: Heat resisting
polyethylene
Durable Temperature: –40 to +150 °C