background image

<13. GENERAL SPECIFICATIONS>

13-17

IM 01F06A00-01EN

Table 13.10 Range of Measurable Saturated Steam Flow Rate at Selected Process Pressures

Model Code

Flow

Rate

Limits

Minimum and Maximum Measurable Flow Rate in kg/h

0.1 MPa 0.2 MPa 0.4 MPa 0.6

MPa

0.8 MPa 1 MPa 1.5 MPa 2 MPa 2.5 MPa 3 MPa

DY015

DY025

/R1

DY040

/R2

min. 5.8(10.7)

7.0(11.1) 8.8(11.6) 10.4(12.1)

11.6(12.3)

12.8

15.3

19.1

23.6

28.1

max.

55.8

80

129

177

225

272

390

508

628

748

DY025

DY040

/R1

DY050

/R2

min. 13.4(18.9)

16.2(20.0)

20.5

24.1

27.1

30

36

41

49

58

max.

169.7

247.7

400

548

696

843

1209

1575

1945

2318

DY040

DY050

/R1

DY080

/R2

min. 26.5(29.2)

32

40.6

47.7

53.8

59

72

93

116

138

max.

405

591

954

1310

1662

2012

2884

3759

4640

5532

DY050

DY080

/R1

DY100

/R2

min.

44.0

53

67.3

79

89

98

119

156

192

229

max.

671

979

1580

2170

2753

3333

4778

6228

7688

9166

DY080

DY100

/R1

DY150

/R2

min.

84.9

103

130

152

171

189

231

300

371

442

max.

1295

1891

3050

4188

5314

6435

9224

12024 14842 17694

DY100

DY150

/R1

DY200

/R2

min.

148

179

227

267

300

330

402

524

647

772

max.

2261

3300

5326

7310

9276

11232 16102 20986 25907 30883

DY150

DY200

/R1

min.

324

392

498

600

761

922

1322

1723

2127

2536

max.

4950

7226

11661

16010

20315

24595 35258 45953 56729 67624

DY200

min.

697

841

1068

1252

1410

1649

2364

3081

3803

4534

max.

8851

12918

20850

28627

36325

43976 63043 82165 101433 120913

DY250

min.

1256

1518

1929

2260

2546

2801

3655

4764

5882

7011

max.

13687

19977

32243

44268

56172

68005 97489 127058 156854

186978

DY300

min.

1799

2174

2762

3236

3646

4012

5235

6823

8423

10041

max.

19602

28609

46175

63397

80445

97390 139614 181960

224633

267772

DY400

min.

3381

4086

5187

6078

6848

8002

11472

14957

18468

22003

max.

32217

47070

75834

104152

132193

160037 229449 299131 369366 440055

(1) Maximum fl ow rate is the lower of 80m/s.
(2) Minimum values are determined from Table 13.7. The values in parenthesis show the minimum linear fl ow rates (Re = 20,000 or