Explosion protected type instrument, 1 atex, Explosion protected type instrument -1 – Yokogawa digitalYEWFLO (DY) User Manual

Page 152: Warning, 1 atex warning

Advertising
background image

<14. EXPLOSION PROTECTED TYPE INSTRUMENT>

14-1

IM 01F06A00-01EN

14. EXPLOSION PROTECTED TYPE

INSTRUMENT

In this chapter, further requirements and differences
for explosion proof type instrument are described
except TIIS Flame proof. For explosion protected
type, the description in this chapter is prior to other
description in this User’s Manual.

WARNING

• Only trained persons use this instrument in

industrial locations.

14.1 ATEX

WARNING

• Only trained persons use this instrument in

industrial locations.

• Electrostatic charge may cause an explosion

hazard.

Avoid any actions that cause the generation

of electrostatic charge, such as rubbing with
a dry cloth on coating face of product.

(1) Technical Data

• Flameproof

Applicable Standard : EN 60079-0: 2009,

EN 60079-1: 2007

Certifi cate : DEKRA 11ATEX0212X
Type of Protection:
Group:

II

Category: 2 G
Ex d IIC T6…T1 Gb (Integral Type Vortex

Flowmeter and Remote Type Vortex Flow
Detector)

Ex d IIC T6 Gb (Remote Type Vortex Flow

Converter)

Specifi cation of Protection:
Process

Temperature:

(Integral Type Vortex
Flowmeter and Remote
Type Vortex Flow
Detector)

Temperature Class

Process Temperature

T6

-29°C to +80°C

T5

-29°C to +100°C

T4

-29°C to +135°C

T3

-29°C to +200°C

T2

-29°C to +300°C

T1

-29°C to +450°C

*1 Note: Use /HT version above 250°C

Temperature Class: T6 (Remote Type Vortex Flow

Converter)

Ambient Temp.:

–29 to +60°C (Integral Type Vortex Flowmeter
and Remote Type Vortex Flow Detector)

–40 to +60°C (Remote Type Vortex Flow
Converter without indicator)

–30 to +60°C (Remote Type Vortex Flow
Converter with indicator)

Power Supply: 10.5 to 42Vdc max.
Output Signal: Current Output; 4 to 20mAdc

Pulse Output; On=2Vdc, 200mA

Off=42Vdc,

4mA

Special Fastener: Class A2-50 or more

• Intrinsically

Safe

Applicable Standard: EN 50014: 1997,

EN 50020: 2002,

EN 50284: 1999

Certifi cate:

KEMA 01ATEX1082X

Type of protection: EEx ia IIC T4…T1 (Integral Type

Vortex Flowmeter and Remote
Type Vortex Flow Detector)

EEx ia IIC T4 (Remote Type

Vortex Flow Converter)

Group: II
Category: 1 G
Degree of Protection of Enclosure: IP67
Tamb.: -29 to +60°C (Integral Type Vortex

Flowmeter)

-29 to +80°C (Remote Type Vortex Flow
Detector)
-40 to +60°C (Remote Type Vortex Flow
Converter)

Advertising