<6. PARAMETERS>

6-2

IM 01F06A00-01EN

(1) Item A : Indication

These items are for the indication of fl owrate and total.

Item

Name

R / W

Data Range

Unit

Decimal

Point

Remark

Initial
Value

Disp. U / D

(*1)

A00 DISPLAY

Menu A (Display)

A10 FLOW RATE (%)

R

0.0 to 110.0

%

1

Flow rate

A20 FLOW RATE

R

0.0 to 65535

FU+C40

0 to 5

Flow rate (in engineering unit)

A30 TOTAL

R

0 to 999999

(*2)

FU

0 to 5

Totalized value

(Indicate only for /MV and B50 : TEMP)

A40 TEMP (%)

(*1)

R

0.0 to 110.0

%

1

Temperature Values (%)

(Indicate only for /MV)

A41 TEMPERATURE

(*1)

R

–999.9 to 999.9

D20

1

Temperature Values

A60 SELF CHECK

R

GOOD
ERROR

Self-diagnostic message

FU : Flow unit
/MV : Multi-Variable (Build-in Temperature Sensor) Type
(*1) : Available for 3.10 or greater version that can be checked in K50.
(*2) : There will be linked to the value of B45, it is displayed “E” shows multipiler 10.

(2) Item B : Easy Setting

These items are for the principal items to operate digitalYEWFLO.
A value in “( )” is the data corresponding to the indicator.

Item

Name

R / W

Data Range

Unit

Decimal

Point

Remark

Initial
Value

Disp. U / D

(*1)

B00 EASY SETUP

Menu B

B10 FLOW SPAN

W

0.00001 to 32000

FU + C40

0 to 5 Flow Span

10

D

L

B15 DAMPING

W

0 to 99

sec

0

Damping Time

4

D

L

B20 CONTACT OUT

W

OFF
SCALED PULSE
UNSCALED PULSE
FREQUENCY
ALARM
FLOW SW(LOW:ON)
FLOW SW(LOW:OFF)

(0)
(1)
(2)
(3)
(4)
(5)
(6)

Contact Output Type

(0)

D

L

(Indicate and Set only for B20: SCALED PULSE, UNSCALED PULSE)

B21 PULSE RATE

W

0.00001 to 32000

FU / P

0 to 5 Pulse Output Rate

1.0

(*3)

D

L

(Indicate and Set only for B20: FREQUENCY)

B22 FREQ AT 100%

W

0 to 10000

PPS

0

Pulse Output Rate at sec /100% 1000

D

L

(Indicate and Set only for B20: FLOW SW (ON), FLOW SW (OFF))

B23 SET LEVEL

W

0.00001 to 32000

FU +C40

0 to 5 Flow Switch (Actual Flow rate)

0

D

L

B30 UPPER DISP

W FLOW RATE (%)

FLOW RATE
TEMP (%)

(0)
(1)
(2)

Selection of Upper Display

(only for /MV)

(0)

(*3)

D

L

B31 LOWER DISP

W BLANK

TOTAL
TEMP

(0)
(1)
(2)

Selection of Lower Display

(only for /MV)

(0)

D

L

B40 TOTAL START

W STOP

START

(0)
(1)

Start / Stop of Totalizer

(0)

D

L

B45 TOTAL RATE

W

0.00001 to 32000

(0)

FU / P

0 to 5 Total Rate

1.0

(*3)

D

L

B47 TOTAL RESET

W

NOT EXECUTE
EXECUTE

(0)
(1)

Totalizer Reset

(0)

D

L

(Indicate and Set only for /MV)

B50 A / OUT SELECT

W

FLOW
TEMP

(0)
(1)

Selection of Analog Output

(0)

D

L

(Indicate and Set only for /MV and B50: TEMP)

B51 TEMP 0%

W

-999.9 to 999.9

D20

1

Set Temperature Value at 0%

-40

D

L

B52 TEMP 100%

W

-999.9 to 999.9

D20

1

Set Temperature Value at 100% 250

(*2)

D

L

B60 SELF CHECK

R

GOOD
ERROR

Self-diagnostic message

FU : Flow unit
(*1) : Available for 3.10 or greater version that can be checked in K50.
(*2) : If 7.00 or less version that can be checked in K50, Initial Value is 260.