<14. EXPLOSION PROTECTED TYPE INSTRUMENT>

14-3

IM 01F06A00-01EN

(3) Operation

WARNING

• Wait 3 min. after power is turned off, before

opening the covers.

• Take care not to generate mechanical

spark when access to the instrument and
peripheral devices in hazardous locations.

(4) Maintenance and Repair

WARNING

• The instrument modifi cation or parts

replacement by other than authorized
representative of Yokogawa Electric
Corporation is prohibited and will void the
certifi cation.

(5) Installation Diagram of Intrinsically safe

(and Note)

DY (flowmeter)

SUPPLY

PULSE

Safety barriers

[Integral type]

Note: In any safety barrier used output current must be limited

by a resistor ‘R’ such that Io=Uo/R

Electric data:
Supply and Output Circuit (SUPPLY

1

and

2

, PULSE

1

and

2

)

Maximum Input Voltage Ui: 30V

Maximum Input Current Ii: 165mA
Maximum Input Power Pi: 0.9W
Internal Capacitance Ci: 6nF
Internal Inductance Li: 0.15mH

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

+

-

+

[Remote type without built-in Temperature sensor]

DYA (flowmeter)

SUPPLY

PULSE

A

B
T

(

*1)

C

A

B

T

Safety barriers

DY-N (flowmeter)

DYC: Signal cable

Hazardous

Non Hazardous

Location

Hazardous

Non Hazardous

Location

F1402.ai

(6) Electrical Connection

The type of electrical connection is stamped near
the electrical connection port according to the
following codes.

F1403.ai

Screw size

ISO M20 X 1.5 female

ANSI 1/2-14NPT female

!

M

!

N

or

!

A

Marking