9) item k : maintenance, These items are for maintenance – Yokogawa digitalYEWFLO (DY) User Manual

Page 46

Advertising
background image

<6. PARAMETERS>

6-10

IM 01F06A00-01EN

(9) Item K : Maintenance

These items are for maintenance.

Item

Name

R / W

Data Range

Unit

Decimal

Point

Remark

Initial
Value

Disp. U / D

(*1)

K00 MAINTENANCE

Menu K (Maintenance)

K10 TLA

W 0.1 to 20.0

1

Trigger Level Adjust

1.0

D

K20 SIGNAL LEVEL

W 0.1 to 20.0

1

Signal Level

1.0

D

K25 N.B. MODE

W AUTO

(0)

MANUAL

(1)

TUNING AT ZERO (2)

Selection of Noise balance Mode

(0)

D

K26 NOISE RATIO

R / W 0.00 to 2.00

2

D

K28 SET VORTEX F

W 0 to 10000

Hz

0 to 5

Output test by setting simulated
frequency.

(*2)

D

K30 VELOCITY

R

m/s

2

Velocity

D

K32 SPAN V

R

Hz

2

Span velocity

D

K34 VORTEX FREQ.

R

Hz

0 to 5

Vortex frequency

D

K36 SPAN F

R

0 to 5

Span frequency

D

(Indicate only for F10: Saturated Steam, Superheat Steam, LIQUID: Mass)

(*1)

K38 DENSITY

R

0.00001 to 32000

D25

0 to 5

Density value (Calculated by
Thermometer)

D

K40 ERROR RECORD

R

Error Records

K45 H VIBRATION

W 0%

(0)

NO ACTION

(1)

Selection of Output Function when
“High Vibration” error is indicated.

(1)

(*3)

K50 SOFTWARE REV

R

0.01 to 99.99

2

Software Revision Number

K60 SELF CHECK

R

GOOD
ERROR

Self-diagnostic message

/MV : Multi-Variable (Build-in Temperature Sensor) Type
(*1) : Available for 3.10 or greater version that can be checked in K50.
(*2) : Available for 5.10 or greater version that can be checked in K50.
(*3) : If 7.00 or less version that can be checked in K50, Initial Value is 0.

(10) Item M : Memo

These items are for Memorandum.

Item

Name

R / W

Data Range

Unit

Decimal

Point

Remark

Initial
Value

Disp. U / D

(*1)

M00 MEMO

Menu M (Memo)

M10 MEMO 1

W 16 characters

W

Memorandum 1

(*2)

M20 MEMO 2

W 16 characters

W

Memorandum 2

(*2)

M30 MEMO 3

W 16 characters

W

Memorandum 3

(*2)

M60 SELF CHECK

R

GOOD
ERROR

R

Self-diagnostic message

(*1) : Available for 3.10 or greater version that can be checked in K50.
(*2) : Available characters are same as C10.

Refer to Section 6.4 “Parameters Description.”