Ped (pressure equipment directive), Ped (pressure equipment directive) -1, Warning – Yokogawa digitalYEWFLO (DY) User Manual

Page 166

Advertising
background image

<15. PED (PRESSURE EQUIPMENT DIRECTIVE)>

15-1

IM 01F06A00-01EN

15. PED (PRESSURE EQUIPMENT

DIRECTIVE)

This chapter is described further requirements and
notices concerning the PED (Pressure Equipment
Directive). The description in this chapter is prior to
other description in this User’s Manual.

(1) Technical Data

Pressure Equipment Directive:

Type of equipment: piping
Type of fl uid: liquid and gas
Group of fl uid: 1 and 2
Assessment: Module H

MODEL

DN(mm)* PS(MPa)* PS·DN(MPa·mm) CATEGORY**

DY015

15

42

630

Article 3,***

Paragraph 3

DY025

25

42

1050

Article 3,***

Paragraph 3

DY040

40

42

1680

II

DY050

50

42

2100

II

DY080

80

42

3360

II

DY100

100

42

4200

II

DY150

150

42

6300

III

DY200

200

42

8400

III

DY250

250

42

10500

III

DY300

300

42

12600

III

DY400

400

25

10000

III

*

PS: Maximum allowable pressure for Flow tube, DN: Nominal
size

**

Refered to Table 6 coverd by ANNEX II of EC Directive on
Pressure Equipment Directive 97/23/EC

*** DY015 and DY025 are not regulated by PED.

(2) Installation

WARNING

• Please take measure to protect the

fl owmeters from forces caused by vibration
through piping.

(3) Operation

WARNING

• The temperature and pressure of fl uid should

be applied under the normal operating
condition.

• The ambient temperature should be applied

under the normal operating condition.

• Please pay attention to prevent the

excessive pressure like water hammer,
etc. When water hammer is to be occurred,
please take measures to prevent the
pressure from exceeding PS (maximum
allowable pressure) by setting the safety
valve, etc. at the system and the like.

• When

external

fi re is to be occurred, please

take safety measures at the device or
system not to infl uence the fl owmeters.

• Please pay attention not to be abrade the

metal pipe, when using the fl uid to abrade
the metal pipe such as slurry and sand are
contained.

Advertising