<13. GENERAL SPECIFICATIONS>

13-14

IM 01F06A00-01EN

Mass fl ow or Volumetric fl ow rate at Normal/Standard condition:

for Multi-Variable Type and combination of Multi-Variable Type and Reduced Bore Type

Model Code

/MV

/MV/R1

/MV/R2

Liquid

DY025

±2.0% (20000

≤Re<1500*D)

±1.5% (1500*D

≤Re)

DY040

±2.0%(20000

≤Re<1000*D)

±1.5% (1000*D

≤Re)

±2.0% (20000

≤Re)

DY050

±2.0% (20000

≤Re)

DY080

DY100

DY150

±2.0% (40000

≤Re<1000*D)

±1.5% (1000*D

≤Re)

DY200

±2.0% (40000

≤Re)

Gas,

Steam

DY025

±2.0%

(Velocity 35m/s or less)

±2.5%

(Velocity 35m/s to 80m/s)

DY040

±2.0%

(Velocity 35m/s or less)

±2.5%

(Velocity 35m/s to 80m/s)

DY050

±2.0%

(Velocity 35m/s or less)

±2.5%

(Velocity 35m/s to 80m/s)

DY080
DY100
DY150
DY200

D: Inner diameter of digitalYEWFLO (mm)
Re: Reynolds number (non unit)
Note: This table shows the accuracy of pulse output. In case of analog output, add up ± 0.1% of full scale to the values mentioned above.

for High Temperature Version Multi-Variable Type and combination of High Temperature Multi-Variable Type and

Reduced Bore Type

Model Code

/HT/MV

/HT/MV/R1

/HT/MV/R2

Liquid

DY025

±2.0% (20000

≤Re<1500*D)

±1.5% (1500*D

≤Re)

DY040

±2.0%(20000

≤Re<1000*D)

±1.5% (1000*D

≤Re)

±2.0% (20000

≤Re)

DY050

±2.0% (20000

≤Re)

DY080

DY100

DY150

±2.0% (40000

≤Re<1000*D)

±1.5% (1000*D

≤Re)

DY200

±2.0% (40000

≤Re)

Gas,

Superheated

Steam

DY025

±2.0%

(Velocity 35m/s or less)

±2.5%

(Velocity 35m/s to 80m/s)

DY040

±2.0%

(Velocity 35m/s or less)

±2.5%

(Velocity 35m/s to 80m/s)

DY050

±2.0%

(Velocity 35m/s or less)

±2.5%

(Velocity 35m/s to 80m/s)

DY080
DY100
DY150
DY200

Saturated

Steam

DY025

±3.0%

(Velocity 35m/s or less)

±3.5%

(Velocity 35m/s to 80m/s)

DY040

±3.0%

(Velocity 35m/s or less)

±3.5%

(Velocity 35m/s to 80m/s)

DY050

±3.0%

(Velocity 35m/s or less)

±3.5%

(Velocity 35m/s to 80m/s)

DY080
DY100
DY150
DY200

D: Inner diameter of digitalYEWFLO (mm)
Re: Reynolds number (non unit)
Note: This table shows the accuracy of pulse output. In case of analog output, add up ± 0.1% of full scale to the values mentioned above.