<14. EXPLOSION PROTECTED TYPE INSTRUMENT>

14-10

IM 01F06A00-01EN

(Integral Type Vortex Flowmeter and Remote Type
Vortex Flow Detector)

Temperature Code

Ambient

Temperature

Process

Temperature

T4 60°C

≤135°C

T3 60°C

≤200°C

T2 60°C

≤300°C

T1 60°C

≤450°C

Temperature Code: T4 (Remote Type Vortex Flow

Converter)

Ambient Temperature: -40 to 60°C
Enclosure: Type 4X
Electrical Parameters: Vmax=30Vdc,

Imax=165mAdc,Pmax=0.9W,
Ci=12nF, Li=0.15mH

(2) Wiring

• Explosion

proof

WARNING

• All wiring shall comply with Canadian

Electrical Code Part I and Local Electrical
Codes.

• In Hazardous locations, wiring shall be in

conduit as shown in the fi gure.

• A SEAL SHALL BE INSTALLED WITHIN

50cm OF THE ENCLOSURE.

• When the equipment is installed in Division

2, “FACTORY SEALED, CONDUIT SEAL
NOT REQUIRED”.

(3) Operation

• Explosion

proof

WARNING

• Note a warning label worded as follows.
Warning: OPEN CIRCUIT BEFORE

REMOVING

COVER.

• Take care not to generate mechanical

spark when access to the instrument and
peripheral devices in hazardous locations.

(4) Maintenance and Repair

WARNING

• The instrument modifi cation or part

replacements by other than authorized
representatives of Yokogawa Electric
Corporation are prohibited and will void CSA
Certifi cation.