6 wiring procedures and precautions, Wiring procedures and precautions -8 – Yokogawa digitalYEWFLO (DY) User Manual

Page 27

Advertising
background image

<4. WIRING>

4-8

IM 01F06A00-01EN

4.6 Wiring Procedures and

Precautions

NOTE

Once all wiring is complete, check the
connections before applying power to the
instrument. Improper arrangements or wiring
may cause a unit malfunction or damage.

(1)

Lay wiring as far as possible from electrical
noise sources such as large capacity
transformers, motors, and power supplies.

(2)

Remove the terminal cover and dustproof plug
of an electrical connection before wiring. When
you open the cover of explosion proof type(*),
turn the Locking Screw to the right, and unlock.
When you close a cover after wiring, be sure to
turn the Locking Screw to the left and lock.

(*) Flameproof(TIIS,ATEX,IECEx), Intrinsically

safe(SAA)

(3)

It recommends using an fl exible metal conduit
and a duct for waterproofi ng or external
protection of an electric wire. Refer to Figure
4.9 and Figure 4.10.

(4)

The fl ameproof packing adapter (option
code: /G11 or /G12) should be used for the
external wiring of TIIS Flameproof. Refer
to “INSTALLATION AND OPERATING
PRECAUTIONS FOR TIIS FLAMEPROOF
EQUIPMENT.”

Terminal Box

Steel Conduit

Flameproof

Converter

F0411.ai

Drain Fitting

Tee

Flexible Metal Conduit

Figure 4.9

Example of Wiring (Integral Type and

Remote Type Detector)

F0412.ai

Terminal Box

Steel Conduit for
Flameproof
Converter

Tee

Drain Fitting

Flexible Metal Conduit

Figure 4.10 Example of Wiring (Remote Type

Converter)

Adapter Body

Packing

Washer

Packing Case

Packing Gland

Clamp Ring

Clamp Nut

B. Coupling

Union Nut

Wrench

O-Ring

Lock Nut

Wrench

Lock Nut

Cable

Apply a nonhardnening
sealant to the threads
for watweproofing

F0413.ai

Figure 4.11 Cable Wiring

NOTE

Be sure to use the fl ameproof packing adapter
(option code:/G11 or /G12) for TIIS fl ameproof
type at the time of cable wiring work. Refer to
Table 4.2.

Table 4.2 Flameproof packing adaptor

Option Code

Diameter for

screw

Cable outer

diameter

mm (inch)

Identifi cation

mark

Parts NO.

G11

G12

G11

G12

ø8.0 to ш10.0

(ш0.31 to ш0.39)

ш10.0 to ш12.0

(ш0.39 to ø0.47)

16 8-10

16 10-12

G9601AM

Advertising