<14. EXPLOSION PROTECTED TYPE INSTRUMENT>

14-12

IM 01F06A00-01EN

14.5 SAA

WARNING

Only trained persons use this instrument in
industrial locations.

(1) Technical Data

• Intrinsically

Safe

Type n

Applicable Standard: AS 2380.1-1989, AS2380.7-

1987, AS2380.9-1991

Certifi cate:

AUS Ex 2611X

Type of Protection: Ex ia IIC T4 IP67 (Integral

Type Flowmeter, Remote Type
Flowmeter and Remote Type
Converter)

Hazardous Area: Class I, Zone 0
Maximum Input Voltage (Ui)=30Vdc
Maximum Input Current (Ii)=165mAdc
Maximum Input Power (Pi)=0.9W
Internal Capacitance (Ci)=37nF
Internal Inductance (Li)=0mH
Ambient Temperature: -20 to +60°C

Type of Protection: Ex n IIC T4 IP67 (Integral

Type Flowmeter, Remote Type
Flowmeter and Remote Type
Converter)

Hazardous Area: Class I, Zone 2
Maximum Input Voltage (Ui)=30Vdc
Ambient Temperature: -20 to +80°C
Electrical Connection : ANSI 1/2 NPT female, ISO

M20X1.5 female.

(2) Installation

WARNING

• All wiring shall comply with local installation

requirements and local electrical code.

• Use the suitable heat-resisting cables for the

digitalYEWFLO Series Vortex Flowmeter
when the process temperature exceeds
+200°C.

• In hazardous locations, the cable entry

devices shall be certifi ed fl ame proof type,
suitable for the conditions of use and
correctly installed.

• Unused apertures shall be closed with

suitable fl ameproof certifi ed blanking
elements.

(3) Operation

WARNING

• Open circuit before opening the covers.
• Take care not to generate mechanical

spark when access to the instrument and
peripheral devices in hazardous locations.

(4) Maintenance and Repair

WARNING

• The instrument modifi cation or parts

replacements by other than authorized
representative of Yokogawa Electric
Corporation are prohibited and will void the
certifi cation.