• Four collars are supplied for 1/2 inch (15mm) to

1- 1/2inch (40mm), 2 inch of JIS 10K or ANSI
class 150, and 3 inch of ANSI class 150. Install
the instrument as illustrated in Table 3.3.

• If the adjacent fl anges have eight bolt holes,

insert the stud bolts in the holes on the
instrument shoulder.

• Stainless steel stud bolts and nuts are available

on order. When they are to be supplied by the
user, refer to Table 3.2 for stud bolt length.
Gaskets must be supplied by the user.

F0311.ai

Pipeline Flange

Pipeline

2. Avoid mounting gaskets which protrude into the

pipeline. This may cause inaccurate readings.

Use gaskets with bolt holes, even if

digitalYEWFLO is of the wafer type.

When using a spiral gasket (without bolt holes),

confi rm the size with the gasket-manufacturer,
as standard items may not be used for certain
fl ange ratings.

Table 3.2 Flange Rating

Size

mm

(inch)

Flange Rating

Major Diameter of

External Threed

of Stud Bolt d

(mm)

Length

(mm)

15mm

(1/2B)

JIS 10K, 20K/DIN 10,
16,25,40
JIS 40K
ANSI 150, 300, 600

12
16

12.7

160
160
155

25mm

(1B)

JIS 10K, 20K, 40K
ANSI 150
ANSI 300, 600
DIN 10, 16, 25, 40

16

12.7
15.9

12

160
155
160
160

40mm

(1-1/2B)

JIS 10K, 20K/DIN 10,
16, 25, 40
JIS 40K
ANSI 150
ANSI 300, 600

16
20

12.7
19.1

160
170
155
170

50mm

(2B)

JIS 10K, 20K, 40K/ DIN
10, 16, 25, 40 ANSI
150, 300, 600

16

15.9

200
200

80mm

(3B)

JIS 10K/DIN 10, 16,
25, 40
JIS 20K, 40K
ANSI 150
ANSI 300, 600

16
20

15.9
19.1

220
240
240
240

100mm

(4B)

JIS 10K/DIN 10, 16
JIS 20K/DIN 25, 40
JIS 40K
ANSI 150
ANSI 300
ANSI 600

16
20
22

15.9
19.1
22.2

220
240
270
240
240
270

Stud Bolt

Collar

d

Length

"

F0310.ai

Advertising