3 maintenance of piping, Maintenance of piping -5, Piping for avoiding bubbles – Yokogawa digitalYEWFLO (DY) User Manual

Page 15: 3) multi-phase flow, 4) pipeline diameter and digitalyewflo, 5) waterproof construction, 1) pipe cleaning, 2) bypass piping

Advertising
background image

<3. INSTALLATION>

3-5

IM 01F06A00-01EN

• Piping for Avoiding Bubbles

Flows containing both gas and liquid cause
problems. Avoid gas bubbles in a liquid fl ow.
Piping should be carried out to avoid bubble
generation.
Install the valve on the downstream side of the
fl owmeter because pressure drop across the
control valve may cause gas to come out of the
solution.

F0304.ai

Flow

Flow

Flow

(Good)

(Good)

(No Good)

Control

Value

(No Good)

(3) Multi-Phase Flow

digitalYEWFLO can measure gas, liquid
and steam when there is no change in state.
However, accurate measurement of mixed
fl ows (e.g. gas and liquid) is not possible.

F0305.ai

(No Good)

(No Good)

Mist flow

(No Good)

Stratified flow

Bubble flow

Liquid
Flow

Gas Flow

(4) Pipeline Diameter and digitalYEWFLO

The process pipeline inner diameter should be
slightly larger than the vortex fl owmeter inner
diameter, schedule 40 or lower pipe should be
used for 1/2 to 2 inch fl owmeters and schedule
80 or lower pipes for 3 to 16 inch fl owmeters.

F0306.ai

(No Good)

(Good)

D

1

D

1

< D

2

D

1

•

D

2

D

2

D

1

D

2

(5) Waterproof Construction

The vortex fl owmeter is of IP67, Type 4X, JIS C
0920 watertight protection. However, it cannot
be used under water.

3.3 Maintenance of Piping

(1) Pipe cleaning

• Flushing of pipe line (Cleaning)

Flush and clean scale, incrustation and sludge
on the inside of pipe wall for newly installed pipe
line and repaired pipe line before the operation.

• Fluid Carrying Solids

Do not measure fl uids that carry solids
(e.g. sand and pebbles). Make sure users
periodically remove solids adhering to the
vortex shedder.

• Obstruction

of

fl ow fl uids may cause to make

a chemical reaction and the fl uid will be
crystallized and hardened, and be deposited on
the pipe wall and shedder bar.
In those cases, clean shedder bar.

(2) Bypass piping

Bypass piping is convenient for the
maintenance of digitalYEWFLO (vortex
shedder cleaning, etc.).

F0307.ai

Flow

Bypass shut-off valve

Upstream shut-off valve

Downstream shut-off valve

digitalYEWFLO