<13. GENERAL SPECIFICATIONS>

13-9

IM 01F06A00-01EN

(Note 5) Refer to Subsection 13.3.1 “Option Multi-Variable (Built-In Temperature Sensor) Type (/MV)”

In case of Remote type detector (DY***-N), select “/MV” both DY and DYA.

(Note 6) /NM can not combine with Remote type (DY***-N).
(Note 7) ATEX Flameproof Approval /KF2 and IECEx Flameproof Approval /SF2 are not Available.
(Note 8) • Cryogenic version /LT is not available.

• High process temperature version /HT and Multi-variable type /MV for DY025/R1 and DY040/R2 is not available.

• Explosion protected types, SAA /SS1 are not available.

Flange type only and available process connections are JIS10k, 20k (BJ1, BJ2) and ANSI class 150, 300
(BA1,BA2,BS1,BS2).

• Model Code (A) means “DY***-” nominal size.

(Note 9) • Applicable for Option code /FF1, /KF2, /KS1, /FS1 and /SF2.

• Not applicable for Option code /P1, /P2, /P7, /X1, /X2, /HT, /LT, /SB /JF3, /FS1, /CF1, /CS1, /CF11, /CS11 and /SS1.

The materials of exterior parts, name plate, screw, bolts on the stainless steel housing and bracket, u-bolt, nuts for DYA/
E1 and tag plate for /E1/SCT are JIS SUS316 or SUS316L.

(Note 10) The wetted parts materials conform to NACE material recommendations per MR0175.

NACE Material /NC can not combine with ASME welding documents submission /WP.

(Note 11) /T01 and /T02 can be selected only one code either.
(Note 12) Refer to Subsection 13.3.2 “Option Reduced Bore Type (/R1, /R2)”

Table 13.3

Paint Color and Codes

Codes Munsell Renotation Code

Color

P1

N1.5

Black

P2

7.5BG4/1.5

Shade green

P7

—————

Metallic silver

Table 13.4

Test Pressure Value

Flange Rating

Pressure

JIS 10 K

2.1 MPa

JIS 20 K

5.0 MPa

JIS 40 K

10.0 MPa

ANSI Class 150

2.9 MPa

ANSI Class 300

7.5 MPa

ANSI Class 600

14.9 MPa

ANSI Class 900

22.4 MPa

DIN PN 10

1.5 MPa

DIN PN 16

2.4 MPa

DIN PN 25

3.8 MPa

DIN PN 40

5.9 MPa

–29

+100

+200

+300

+450

+85

+60

–29

)OXLG7HPSHUDWXUH Û&

$PELHQW7HPSHUDWXUH Û&

Operating range

F1304.ai

Figure 13.4 Fluid Temperature Range of High

Process Temperature Version

–196

–100

–29

0

0

–50

–20

)OXLG7HPSHUDWXUH Û&

$PELHQW7HPSHUDWXUH Û&

Operating range

+100

F1305.ai

–29

Figure 13.5 Fluid Temperature Range of Cryogenic

Version