Important – Yokogawa digitalYEWFLO (DY) User Manual

Page 32

Advertising
background image

<5. BASIC OPERATING PROCEDURES>

5-4

IM 01F06A00-01EN

5.3.1 Changes to Engineering Display Unit from % Display

The display mode can be changed referring to Section 6.3 “Parameters List.”

SET

INC

SHIFT

SET

INC

SHIFT

SET

INC

SHIFT

SET

INC

SHIFT

SET

INC

SHIFT

SET

INC

SHIFT

SET

INC

SHIFT

SET

INC

SHIFT

SET

INC

SHIFT

F0504.ai

Indication of %
display.

Enter the setting
mode.

Enter the parameter
item.

Indicate “ 30 ”.

Enter the data
input item.

Indicate “ 01 ” of
engineering unit.

Ensure the setting
data.

Finish the setting.

Return to display
mode.

Press “ SET ” key.

Press “ SHIFT ” key.

Press “ INC ” key any time.

Press “ SET ” key.

Press “ INC ” key.

Press “ SET ” key.

Press “ SET ” key.

Press “ SET ” and “ SHIFT ” key.

IMPORTANT

After setting a parameter, keep the power on for
at least 30 seconds.
If the power of fl owmeter is turned off, a
parameter setting is released.

Advertising