8.4

List of Commands

Parameters common for preceding styles (PR201S1.0, UZ005S2.0)

Parameter

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

Meaning

Read measured values in batch.

Read electric energy

Read optional electric (Previous value)

energy *1

(Current value)

Instantaneous power

Instantaneous voltage-1

Instantaneous current-1

Instantaneous power factor

Start optional integration *1

Stop optional integration *1

Maximum/minimum values initialization

Read measured value and

maximum/minimum values in batch

Read maximum voltage-1 value

Read minimum voltage-1 value

Read maximum current-1 value

Read maximum current-2 value

Size

46 bytes

5 bytes

10 bytes

9 bytes

8 bytes

8 bytes

6 bytes

0 byte

0 byte

0 byte

70 bytes

8 bytes

8 bytes

8 bytes

8 bytes

Format

Response data

Range

Resolution

Data of parameters 1 to 5 and 6 (power factor measurement)

No data

No data

No data

Data of parameters 1 to 6 and B to D

ٗٗٗٗٗ
ٗٗٗٗٗ
ٗٗٗٗٗ
Ϯٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

᭝ٗ

.

ٗٗٗ

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

00000 to 99999 [kWh]

00000 to 99999 [Wh]

00000 to 99999 [Wh]

Ϯ

0 to

Ϯ

9.999E

ϩ

6 [W]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

5 [A]

D0.500 to G1.000 to G0.500

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

5 [A]

0 to 9.999E

ϩ

5 [A]

1[kWh]

1[Wh]

1[Wh]

0.001E

ϩ

2[W]

0.001E

ϩ

2[V]

0.001E

ϩ

0[A]

0.001

0.001E

ϩ

2[V]

0.001E

ϩ

2[V]

0.001E

ϩ

0[A]

0.001E

ϩ

0[A]

Command: DG

2

3

4

5

6

7

8

9

B

C

D

F

G

H

J

K

L

M

N

P

Q

R

S

T

U

V

W

X

Y

Z

Read optional electric (Previous value)

energy *1

(Current value)

Instantaneous power

Instantaneous voltage-1

Instantaneous current-1

Instantaneous power factor

Start optional integration *1

Stop optional integration *1

Maximum/minimum values initialization

Read maximum voltage-1 value

Read minimum voltage-1 value

Read maximum current-1 value

Read measured values in batch

Read electric energy

Instantaneous voltage-2

Instantaneous voltage-3

Instantaneous current-2

Instantaneous current-3

Read measured value and

maximum/minimum values in batch

Read maximum voltage-2 value

Read maximum voltage-3 value

Read minimum voltage-2 value

Read minimum voltage-3 value

Read maximum current-2 value

Read maximum current-3 value

–––

–––

–––

Read model and suffix codes

–––

Error response

10 bytes

9 bytes

8 bytes

8 bytes

6 bytes

0 byte

0 byte

0 byte

8 bytes

8 bytes

8 bytes

81 byte

8 bytes

8 bytes

8 bytes

8 bytes

8 bytes

153 bytes

8 bytes

8 bytes

8 bytes

8 bytes

8 bytes

8 bytes

14 bytes

2 bytes

Data of parameters G, 2, 3, 4, H, J, 5, K, L, 6

(power factor measurement), B, C, D and N to T

Data of parameters G, 2, 3, 4, H, J, 5, K, L and 6

(power factor measurement)

No data

No data

No data

PR201-

ٗٗٗٗٗ

-

᭝᭝

ٗٗ

ٗٗٗٗٗ
ٗٗٗٗٗ
Ϯٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

᭝ٗ

.

ٗٗٗ

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗٗٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

ٗ

.

ٗٗٗ

E

ϩ᭺

00000 to 99999 [Wh]

00000 to 99999 [Wh]

Ϯ

0 to

Ϯ

9.999E

ϩ

6 [W]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

5 [A]

D0.500 to G1.000 to G0.500

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

5 [A]

00000E

ϩ

3 to 99999E

ϩ

6 [Wh]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

5 [A]

0 to 9.999E

ϩ

5 [A]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

6 [V]

0 to 9.999E

ϩ

5 [A]

0 to 9.999E

ϩ

5 [A]

1[Wh]

1[Wh]

0.001E+2[W]

0.001E+2[V]

0.001E+0[A]

0.001

0.001E+2[V]

0.001E+2[V]

0.001E+0[A]

0.001E+2[V]

0.001E+2[V]

0.001E+0[A]

0.001E+0[A]

0.001E+2[V]

0.001E+2[V]

0.001E+2[V]

0.001E+2[V]

0.001E+0[A]

0.001E+0[A]

Parameter

Meaning

Size

Format

Response data

Range

Resolution

*1:

When optional integration is started or stopped through communication, the subsequent optional integration control
signals are disabled. For this reason, optional integration must be controlled by either communication or optional
integration control signals. After a power failure, optional integration control is reset.

Advertising