Example

Reads the measured value and maximum/minimum values of PR300 with station number
01 in batch.

ᮀᮀ

indicates the checksum value.

[Command]

[STX]DGM01

ᮀᮀ

[ETX][CR]

Returns the following response for the above command.

[Response]

[STX]DGM0110000E+31000010000+1.000E+31.000E+31.000E+31.000E+3

1.000E+31.000E+31.000E+3G0.8001.000E+31.000E+21.000E+3

1.000E+31.000E+31.000E+21.000E+21.000E+31.000E+3

ᮀᮀ

[ETX][CR]

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(12)

(13)

(14)

(11)

(15)

(16)

(17)

(18)

(19)

(20)

(1) Active energy: 10000E+3 Wh (10 MWh), (2) Optional electric energy (previ-
ous value): 10000 Wh, (3) Optional electric energy (current value): 10000 Wh,
(4) Active power: +1.000E+3 W (1000 W), (5) Voltage-1: 1.000E+3 V (1000 V),
(6) Voltage-2: 1.000E+3 V (1000 V), (7) Voltage-3: 1.000E+3 V (1000 V),
(8) Current-1: 1.000E+3 A (1000 A), (9) Current-2: 1.000E+3 A (1000 A),
(10) Current-3: 1.000E+3 A (1000 A), (11) Power factor: G0.800, (12) Maximum
voltage-1: 1.000E+3 V (1000 V), (13) Minimum voltage-1: 1.000E+ 2 V (100 V),
(14) Maximum current-1: 1.000E+3 A (1000 A), (15) Maximum voltage-2:
1.000E+3 V (1000 V), (16) Maximum voltage-3: 1.000E+3 V (1000 V),
(17) Minimum voltage-2: 1.000E+2 V (100 V), (18) Minimum voltage-3:
1.000E+2 V (100 V), (19) Maximum current-2: 1.000E+3 A (1000 A),
(20) Maximum current-3: 1.000E+3 A (1000 A).

Parameter: X (Reads model and suffix codes)

• Function

Returns the model and suffix codes of PR300.

• Command/response

Number

of bytes

1

2

1

2

2

1

1

Command

element

STX

DG

X

Station

number

(ADR)

Checksum ETX

CR

There is no command data for data reading.

1

2

1

2

14

Response

element

STX

DG

X

Station

number

(ADR)

PR201-

ٗٗٗٗٗ

-

᭝᭝

(Note 1)

2

1

1

Checksum ETX

CR

Number

of bytes

Response data is returned in a 14-byte ASCII character string.