4.1.3

Response Error Codes

See Also

4.1.2, “Configuration of Response”, for the configuration of response in the event of error.

The error codes (EC1) and detailed error codes (EC2) of responses are as follows.

Table 4.1 List of Error Codes EC1

Meaning

Cause(s)

• No command exists.
• Command not executable
• No register number exists.

• A value other than hexadecimal values (0 to 9, A to F) has been specified in word
specification.
• The position of a start for a data load/save or other command is out of the
address range.
• The specification of the number of words is out of the specified range.
• An attempt was made to execute monitoring without specifying the monitor
(WRS).
• An illegal parameter is set.

Parameter error

• The sum does not match the expected value.

Internal buffer overflow

Command error

Register specification error

Out of setpoint range
(when in writing operation)

Out of data count range
Monitor error

Checksum error

Character reception timeout

• A data value greater than the specified was received.

02

Error
Code

03

04

05
06

08
42
43
44

• The end-of-data or end-of-text character has not been received.

Table 4.2 List of Detailed Error Codes EC2

Detailed Error Code (EC2)

Error Code (EC1)

Register specification error

Out of setpoint range

Out of data count range

03

04

05

08

Parameter error

Meaning

Parameter number where error occurred (HEX)
This is the sequence number of a parameter that first resulted
in an error when counted from the leading parameter.

e.g.:

Register name specification error

[STX]01010WRW02D0043,3F80,A0044,0000[ETX][CR]

Parameter numbers 1

2

3

4

5

[STX]0101ER0304WRW[ETX][CR]

In this case, EC1=03 and EC2=04.

For error codes other than those noted as EC1, there is no EC2 meaning, and 0x00 is
returned as a response.