Command/response, Example – Yokogawa PR300 Power and Energy Meter User Manual

Page 126

Advertising
background image

<Toc> <Ind>

<8. PR201 Original Communication Protocol>

8-11

IM 77C01E01-10E

Parameter: 8 (Stops optional integration)

• Function

Stops optional integration.

• Command/response

Number

of bytes

1

2

1

2

2

1

1

Command

element

STX

DG

8

Station

number

(ADR)

Checksum ETX

CR

There is no command data for data reading.

1

2

1

2

0

Response

element

STX

DG

8

Station

number

(ADR)

No data

2

1

1

Checksum ETX

CR

Number

of bytes

There is no response data.

• Example

Stops optional integration of PR300 with station number 01.

ᮀᮀ

indicates the checksum

value.

[Command]

[STX]DG801

ᮀᮀ

[ETX][CR]

Returns the following response for the above command.

[Response]

[STX]DG801

ᮀᮀ

[ETX][CR]

Parameter 9: (Initializes maximum and minimum values)

• Function

Initializes the maximum and minimum values (maximum and minimum values of voltage-1
to voltage-3 and maximum value of current-1 to current-3)

• Command/response

Number

of bytes

1

2

1

2

2

1

1

Command

element

STX

DG

9

Station

number

(ADR)

Checksum ETX

CR

There is no command data for data reading.

1

2

1

2

0

Response

element

STX

DG

9

Station

number

(ADR)

No data

2

1

1

Checksum ETX

CR

Number

of bytes

There is no response data.