NORD Drivesystems BU0750 User Manual

Page 101

Advertising
background image

7.6 Control clamps

BU 0750 GB-3311

Subject to technical amendments

101

Parameter

Setting value / Description / Note

Parameter
set

Available with option

P420

Function of digital input 1

BSC

STD

MLT

BUS

0 ... 48

[ 1 ]

Enable right as factory setting

Various functions can be programmed. These can be seen in the following table.

P421

Function of digital input 2

BSC

STD

MLT

0 ... 48

[ 2 ]

Enable left as factory setting
Various functions can be programmed. These can be seen in the following table.

P422

Function of digital input 3

BSC

STD

MLT

0 ... 48
[ 8 ]

Parameter set switching as factory setting

Various functions can be programmed. These can be seen in the following table.

P423

Function of digital input 4

STD

MLT

0 ... 48
[ 4 ]

Fixed frequency 1 as factory setting
Various functions can be programmed. These can be seen in the following table.

P424

Function of digital input 5

MLT

0 ... 25
[ 0 ]

No function as factory setting

Various functions can be programmed. These can be seen in the following table.

P425

Function of digital input 6

MLT

0 ... 25
[ 0 ]

No function as factory setting

Various functions can be programmed. These can be seen in the following table.