NORDAC SK 750E Manual

118

Subject to technical amendments

BU 0750 GB-3311

Parameter

Setting value / Description / Note

Parameter
set

Available with option

P549

Function PotentiometerBox

Always visible

0 ... 13
[ 1 ]

In this parameter, a function is assigned to the potentiometer value output when control is via the
potentiometer option. (An explanation can be found in the description of P400)

0 = Off

1 = Setpoint frequency

2 = Torque current limit

3 = Actual frequency PID

4 = Frequency addition

5 = Frequency subtraction

6 = Current limit

7 = Maximum frequency

8 = Actual PID frequency limited

9 = Actual PID frequency monitored

10 = Torque

11 = Lead torque

12 = No function

13 = Multiplication

P550

Save dataset

Always visible

0 ... 3
[ 0 ]

It is possible to save a dataset (parameter set 1 to 4) of the connected FI in the optional
ControlBox. This is saved inside the Box in a non-volatile memory and can therefore be transferred
to other NORDAC 750E devices with the same databank version (compare P743).

Caution:

In deviation from the statement in Section 3.2, Overview of technology units, this
function can only be used in the rright hand slot. If no BUS module is used, the
ControlBox can also be used in the right hand slot with the full range of functions.

0 = No function

1 = FI

ControlBox, the dataset is written from the connected FI to the ControlBox.

2 = ControlBox

FI, the dataset is written from the ControlBox to the connected FI.

3 = FI



ControlBox, the FI dataset is exchanged with the ControlBox dataset. With this

variant, no data is lost. It is continuously exchangeable.

Note:

If parameterisation from old FI's must be loaded into new FI's, then the ControlBox
must previously be written to by the new FI (=1). The dataset to be copied from the old
FI can then be read out and copied to the new FI.

P551

Drive profile

Always visible

0 / 1

According to the option the relevant process data profiles can be activated with this parameter.

This parameter is only effective for plug-in technology modules (SK TU1-

…)

Note:

With the use of the internal CANbus (CANnord) via the integrated customer
interface (SK CU1-

…), the settings in this parameter have no effect. The

DS402 profile cannot be activated.

System

CANopen *

DeviceNet

InterBus

Technology module

SK TU1-CAO

SK TU1-DEV

SK TU1-IBS

Setting

0 =

USS protocol (Profile "Nord")

1 =

DS402 profile

AC Drives profile

Drivecom profile