NORD Drivesystems BU0750 User Manual

Page 124

Advertising
background image

NORDAC SK 750E Manual

124

Subject to technical amendments

BU 0750 GB-3311

Parameter

Setting value / Description / Note

Parameter
set

Available with option

P744

Configuration

Always visible

0 ... 9999

The option modules recognised by the frequency inverter are displayed in this parameter.

The display with the ParameterBox is in plain text.

The possible combinations are displayed in code in the ControlBox. The Customer Units in use
are displayed on the right. If another Encoder module is installed, this is indicated in the second
digit with a 1, the option PosiCon is indicated with a 2.

No I/O

XX00

Basic I/O

XX01

Standard I/O

XX02

Multi I/O

XX03

USS I/O

XX04

CAN I/O

XX05

Profibus I/O

XX06

Encoder

01XX

PosiCon

02XX

P745

... - 01

... - 02

... - 03

Module version

Always visible

0 ... 32767

Software version of the integrated

modules (only when own

processor is present).

Array level:

[01] Technology unit

[02] Customer Unit

[03] Special Extension Unit

P746

... - 01

... - 02

... - 03

Module status

Always visible

0000 ... FFFF hex

Status of the installed modules

(if active)

Array level:

[01] Technology unit

[02] Customer Unit

[03] Special Extension Unit

P747

Inverter voltage range

Always visible

1 / 2

Indicates the mains voltage range for which this device is specified.

1

= 200 … 240V

2

= 380 … 480V

P750

Overcurrent statistic

Always visible

0 ... 9999

Number of overcurrent messages during the operating period.

P751

Overvoltage statistic

Always visible

0 ... 9999

Number of overvoltage messages during the operating period.