4.6 ParameterBox error messages

BU 0750 GB-3311

Subject to technical amendments

71

Display

Fault

Cause

Remedy

222

Inverter extension level not
recognised

An unknown module has been detected in the frequency inverter
(Customer interface).

Please check the components installed in the
frequency inverter

If necessary, check the software version of the
ParameterBox and the frequency inverter.

223

Bus configuration has
changed

After restoring the last Bus configuration, a device is reported that is
different from the one stored.
This error can only occur if the parameter >Auto Bus Scan< is set to
OFF and another device has been connected to the ParameterBox.

Activate the Automatic Bus Scan function.

224

Device is not supported

The frequency inverter type connected to the ParameterBox is not
supported!

The ParameterBox cannot be used with this frequency
inverter.

225

The connection to the
inverter is blocked

Access to a device that is not ONLINE (previously Time Out error).

Carry out a bus scan via the parameter >Bus Scan<
(P1001).

ParameterBox operating error

226

Source and target are
different devices

Copying objects of different types (from / to different inverters) is not
possible.

227

Source is empty

Copying of data from a deleted (empty) storage medium

228

This combination is not
permitted

Target and source for the copying function are the same. The
command cannot be carried out.

229

Object selected is empty

Parameterisation attempt of a deleted storage medium

230

Different software versions

Warning
Copying objects with different software versions can lead to problems
when transferring parameters.

231

Invalid password

Attempt to alter a parameter without a valid Box password being
entered in parameter >Box password< P 1306.

232

Bus scon only during
operation: ONLINE

A bus scan (search for a connected frequency inverter) is only possible
when in ONLINE mode.