Nordac < frequency inverter – NORD Drivesystems BU0750 User Manual

Page 61

Advertising
background image

4.4 Functions of the ParameterBox

BU 0750 GB-3311

Subject to technical amendments

61

Display

After the ParameterBox is connected and the mains voltage for the inverter is switched on, an automatic "Bus
scan"
is performed. The ParameterBox identifies the connected frequency inverter(s). The frequency inverter
type and its actual operating status can be seen in the following display.

750E 11.0kW/3 POS STD

1

> NORDAC <

Frequency inverter

ONLINE

FI1

P1

EReady

Actual status of

the inverter

Inverter type


In the standard display mode, 3 operating values and the actual frequency inverter status can be displayed
simultaneously.
The operating values displayed can be selected from a list of 8 possible values (in Menu>Display</>Values for
display< P1004).

750E 11.0kW/3 POS STD

1

Fi/Hz

U/V

I/A

45.0

190

1.4

ONLINE

FI1

P1

R RUNNING

Current actual values for

the selected operating

values and their

applicable units

Current
ParameterBox status

Inverter selected

Active parameters
in inverter

Actual status of the
inverter

Inverter type

Menu structure level

Special extension unit
Customer interface



NOTE

The digital frequency setpoint is factory set to 0Hz. To check whether the motor is working, a

frequency setpoint must be entered with the

key or a jog frequency via the respective menu

level >Parameterise<, >Base parameters< and the respective parameter >Jog frequency<
(P113).
Settings should only be implemented by qualified personnel, strictly in accordance with the
warning and safety information.

CAUTION: The drive may start immediately after pressing the START key

!