3.6 Colour and contact assignments for the incremental encoders

Function

Cable colours,

for incremental encoder

Assignment for encoder option

SK XU1-ENC

Assignment for encoder option

SK XU1-POS

15 V supply

brown / green

X11.1.42 VO +15V

X10.2.42 VO +15V

0 V supply

white / green

X11.1.40 GND /0V

X10.4.40 GND /0V

Track A

brown

X11.2.51 ENC1 A+

X10.4.51 ENC1 A+

Track A inverse

green

X11.2.52 ENC1 A-

X10.4.52 ENC1 A-

Track B

grey

X11.2.53 ENC1 B+

X10.4.53 ENC1 B+

Track B inverse

pink

X11.2.54 ENC1 B-

X10.4.54 ENC1 B-

Track 0

red

--

X10.4.55 ENC1 N+

Track 0 inverse

black

--

X10.4.56 ENC1 N-

Cable shield

connected to a large area of the frequency inverter housing or shielding angle

NOTE

If there are deviations from the standard equipment (A.772.4) for the motors, please note the
accompanying data sheet or consult your supplier.

RECOMMENDATION: For greater reliability, in particular with long connection cables, we recommend the use of a higher

power supply (15V/24V) and an incremental encoder for 10-30V power supply. The signal level must
still be 5V TTL.

ATTENTION

The rotation field of the incremental encoder must correspond to that of the motor. Because of
this, according to how the encoder is mounted on the motor (possible mirror image), tracks A+
and A- may need to be switched over or a negative sign entered in parameter P301. For
SK 750E, inverted mounting has already been taken into account!