4.7 NORD CON

BU 0750 GB-3311

Subject to technical amendments

73

4.7 Data transfer with NORD CON

The storage elements S1 to S5 of the NORDAC ParameterBox can be managed and archived with the NORD
CON
control and parameterisation software.
To achieve transfer of data, the PC serial interface (RS232) must be connected to the ParameterBox via an
interface converter (SK IC1-232/485, Part. No. 276970020) and suitable connection cable. (M12 Socket/SUB-
D, Part. No. 278910210). In addition, the interface inverter must be connected to an external supply voltage.
Use the USB/5V adapter (Part No. 278910220) for this, which is connected to the interface converter via a
cinch connector and to the PC/laptop via a USB connector.

The following components are required to connect the ParameterBox to the PC/Laptop benötigt:

5V-USB-Port

Adapter

PC / Laptop

ParameterBox

SK PAR-2H

Part No. 278910100

Adapter M12 So/SUB-D

for SK PAR-2H  SK IC1

Part No. 278910210

Interface converter

SK IC1-232/485

Part No. 276970020

Software

NORD CON

Part No. 206099985

(NORD PAC)

www.nord.com

USB/5V adapter for

SK IC1-232/485

Part No. 278910220

RS232

In this configuration, communication is controlled by the PC. For this, the ParameterBox must be set to the
value PC slave, in the menu group >Options< parameter >Operating mode (P1302)< . After a bus scan,
NORD CON program will then detect the filed storage objects S1 to S5 as separate frequency inverters with
bus addresses 1 to 5 and display them on the screen.

NOTE

Only storage objects saved in the frequency inverter parameter data sets can be detected and
processed by the NORD CON parameterisation software.
To edit the data set of a new frequency inverter, the inverter type first has to be set via the >Load
default values (P1204)<
parameter. The NORD CON software then detects the new storage
object in a new bus scan. The new parameter data set can then be edited with the usual tools.

All NORD CON parameterisation
functions are now available.