Parameter

Setting value / Description / Note

Parameter
set

Available with option

P546

Bus setpoint 1

P

Always visible

0 ... 7
[ 1 ]

In this parameter, a function is allocated to the output setpoint 1 during bus actuation.
Note: Further details can be found in the respective BUS instruction manuals.

0 = Off

1 = Setpoint frequency (16 Bit)

2 = 16 Bit setpoint position (only with option PosiCon, SK 750E)

3 = 32 Bit setpoint position (only with Option PosiCon, SK 750E

and if PPO type 2 or 4 has been selected)

4 = Control terminals PosiCon

3

(only with Option PosiCon, SK 750E, 16Bit)

5 = Setpoint position (16 Bit) increment

2

(only with PosiCon, SK 750E)

6 = Setpoint position (32Bit) increment

2

(only with PosiCon, SK 750E)

7 = Bus I/O In B

its 0 … 7

P547

Bus setpoint 2

P

Always visible

0 ... 20
[ 0 ]

In this parameter, a function is allocated to the output setpoint 2 during bus actuation.
Note: Further details can be found in the respective BUS instruction manuals.

0 = Off
1 = Setpoint frequency
2 = Torque current limit
3 = Actual frequency PID
4 = Frequency addition
5 = Frequency subtraction
6 = Current limit
7 = Maximum frequency
8 = Actual PID frequency

limited

9 = Actual PID frequency

monitored

10 = Torque
11 = Lead torque
12 = Control terminals PosiCon

3

(only with PosiCon option)

13 = Multiplication
14 = Process controller actual value
15 = Process controller setpoint
16 = Process controller lead
17 = Bus IO In Bits 0-7
18 = Curve travel calculator
19 = Set relay (P541)

20 =

Set analog output (P542)

P548

Bus setpoint 3

P

Always visible

0 ... 20
[ 0 ]

In this parameter, a function is allocated to the output setpoint 3 during bus actuation. It is only
present when P546

3.

Note: Further details can be found in the respective BUS instruction manuals.

This parameter is identical to P547.

3

The "reference run", "teach-in" and "reset position" can be controlled via the other Bits:

2

Bit 0: Position array / Position increment array

Bit 1: Position array / Position increment array

Bit 2: Position array / Position increment array

Bit 3: Position array / Position increment array

Bit 4: Position array / Position increment array

Bit 5: Position array / Position increment array

Bit 6: Reference point run

Bit 7: Reference point

Bit 8: Teach-In

Bit 9: Quit Teach-In

Bit 10: Reset position