7.2 Operating displays

BU 0750 GB-3311

Subject to technical amendments

81

7.2 Operating displays

In the following, the abbreviation FIwill be used for a frequency inverter.

Parameter

Setting value / Description / Note

Parameter
set

Available with option

P000

Operating display

Always visible

Only with the Option ControlBox according to selection in P001.
The operating parameter selected in P001 will be displayed here.

P001

Selection display

Always visible

0 ... 17
[ 0 ]

0 =

Actual frequency [Hz], is the actual output frequency being supplied by the FI.

1 =

Speed [rpm], the actual speed calculated by the FI.

2 =

Setpoint frequency [Hz], the output frequency equivalent to the actual setpoint. This need not
match the actual output frequency.

3 =

Current [A], the actual output current measured by the FI.

4 =

Torque current [A], the torque developing output current of the FI.

5 =

Voltage [Vac], the actual alternating voltage being output by the FI.

6 =

Link voltage [Vdc], the FI-internal DC voltage. Amongst other things, this depends on the
level of the mains voltage.

7 =

cos

, the actual calculated value of the power factor.

8 =

Apparent power [kVA], the actual apparent power calculated by the FI.

9 =

Effective power [kW], the actual effective power calculated by the FI.

10 =

Torque [%], the actual torque calculated by the FI.

11 =

Field [%], the actual field in the motor calculated by the FI.

12 =

Operating hours [h], time that voltage is applied to the FI network.

13 =

Enabled operating hours [h], time that the FI is enabled.

14 =

Analog input 1 [%] *, actual value present at analog input 1 of the FI.

15 =

Analog input 2 [%] *, actual value present at analog input 2 of the FI.

16 =

Position setpoint **, desired control position.

17 =

Actual position **, actual position of the drive.

*)

Only advisable if the customer unit has the appropriate inputs.

**)

Only with special extension PosiCon.

P002

Factor display

Always visible

0.01 ... 999.99
[ 1.00 ]

The operating value in parameter P001 >Selection of operating value display< is scaled with the scaling
factor and displayed in P000. It is therefore possible to display system-specific operating values such
as bottles per hour.