NORD Drivesystems BU0750 User Manual

Page 83

Advertising
background image

7.3 Basic parameters

BU 0750 GB-3311

Subject to technical amendments

83

Parameter

Setting value / Description / Note

Parameter
set

Available in Option

P104

Minimum frequency

P

Always visible

0.0 ... 400.0 Hz
[ 0.0 ]

The minimum frequency is the frequency supplied by the FI as soon as it is enabled and no
additional setpoint is set.
In combination with other setpoints (e.g. analog setpoint or fixed frequencies) these are added to the
set minimum frequency.
This frequency is undershot when

a. the drive is accelerated from standstill.
b. The FI is blocked. The frequency then reduces to the absolute minimum (P505) before it is

blocked.

c. The FI reverses. The reverse in the rotation field takes place at the absolute minimum

frequency (P505).

This frequency can be continuously undershot if, during acceleration or deceleration, the function
"Maintain frequency" (Function Digital input = 9) is executed.

P105

Maximum frequency

P

Always visible

0.1 ... 400.0 Hz
[ 50.0 ]

The frequency supplied by the FI after being enabled and once the maximum setpoint is present,
e.g. analog setpoint as per P403, a correspondingly fixed frequency or maximum via the ControlBox.
This frequency can only be overshot by the slip compensation (P212), the function "Maintain
frequency" (function digital input = 9) or a change to another parameter set with lower maximum
frequency.

P106

Ramp rounding

P

Always visible

0 ... 100 %
[ 0 ]

This parameter enables a smoothing of the acceleration and deceleration ramps. This is necessary
for applications where gentle, but dynamic speed change is important.
Ramp smoothing is carried out for every setpoint change.
The value to be set is based on the set acceleration and deceleration time, however values <10%
have no effect.
The following then applies for the entire acceleration or deceleration time, including rounding:

 

100%

%

P106

t

t

t

P102

P102

TIME

ON

ACCELERATI

tot

 

100%

%

P106

t

t

t

P103

P103

TIME

ON

DECELERATI

tot


P102

P103

Output

frequency

Setpoint

frequency

Time

Each
10

– 100% of P102

Each
10

– 100% of P103


Advertising