Device type

max. cable length, shielded

without aux. line filter

SK 750E-551-323-

A … SK 750E-112-323-A

Class A

25m

SK 750E-551-340-

A … SK 750E-222-340-A

Class A

25m

Overview of standards that, as per EN 61800-3 (product standard for frequency

inverters) are based on EN 50081; 510082 and must be complied with

Standard

Limit value class

Emission of interference

Cable-related emission

EN55011

"A"

"B" with filter

Radiated emission

EN55011

"A"

"B" with filter, built into control cabinet

Immunity from interference

ESD, discharge of static electricity

EN61000-4-2

6kV (CD), 8kV (AD)

EMF, high frequency electro-
magnetic fields

EN61000-4-3

10V/m; 26-1000MHz

Burst on control cables

EN61000-4-4

1kV

Burst on mains and motor cables

EN61000-4-4

2kV

Surge (phase-phase / phase-ground)

EN61000-4-5

1kV / 2kV

Cable-led interference due to high
frequency fields

EN 61000-4-6

10V, 0.15

– 80MHz

Voltage fluctuations and drops

EN61000-2-1

+10%, -15%; 90%

Voltage asymmetries and
frequency changes

EN61000-2-4

3%; 2%


Wiring recommendations

M

3 ~

PE

L

1

W

V

U

W

V

U

200-240V

or

360-480V

50-60Hz

L

1

L

2

PE

L

2

L

3

L

3

PE

B-

B+

NORDAC SK 750E

Shield angle or
screw connection

Brake resistor

(Accessories)